{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60642","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60642","canonicalUrl":"https://aoctrl.com/schneider/MGN60642","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60642","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60642 miniature circuit-breaker, 3-pole, 25 A, C-curve, 30 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The MGN60642 is a 3-pole C60H miniature circuit-breaker from the Multi9 range, rated 25 A at 50 °C with a C-curve trip characteristic. The headline breaking capacity is 30 kA Icu at 240 V AC phase-to-phase, dropping to 15 kA at 415 V AC and 10 kA at 440 V AC. For DC circuits it's rated 25 kA at 125 V DC. The Ics (service breaking capacity) is 50 % of Icu across the AC voltages — so at 240 V AC that's 15 kA, and at 125 V DC it's 40 kA at 100 %. The 30 kA rating at 240 V AC gives headroom for high-fault installations near transformers or large motor banks. Strip length is 14 mm on the power circuit. The 54 mm width (6 x 9 mm pitches) means it occupies three modular spaces on the rail. IP20 finger-safe protection is standard for the enclosure; the busbar and distribution block can be fed from top or bottom.","metaTitle":"MGN60642 C60H MCB, 25 A C-curve 3P, 30 kA","metaDescription":"MGN60642 C60H miniature circuit-breaker, 25 A rated current, C-curve, 3 poles, 30 kA breaking capacity at 240 V AC. EN/IEC 60947-2. Active production. Available to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"25 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 40 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/87fbb438ccb6a190d95561ada3d4ef70.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60642/c60-circuit-breaker-c60h-3p-25a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60642/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60642 and get a price?","answer":"The MGN60642 is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing — no stock or price figures are published here."},{"question":"What is the closest alternative to MGN60642 in this family?","answer":"Within the C60H range, the direct sibling is the same 3-pole C-curve 25 A breaker with identical breaking capacity ratings. The only difference would be a different order code suffix for packaging or regional variant — the functional specs are interchangeable for a BOM replacement."},{"question":"What is MGN60642's depth?","answer":"The MGN60642 has a depth of 73 mm, with a width of 54 mm and height of 81 mm."},{"question":"What range does MGN60642 belong to?","answer":"It belongs to the Multi9 range, specifically the C60H series of miniature circuit-breakers."},{"question":"What compliance documentation does MGN60642 carry?","answer":"The MGN60642 is designed and tested to EN/IEC 60947-2. It carries a pollution degree 3 rating and IP20 protection. Specific RoHS, REACH, or UL documentation should be confirmed at quote time — the standard certification is to the IEC 60947-2 product standard for low-voltage switchgear."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60642","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60642 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}