{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60647","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60647","canonicalUrl":"https://aoctrl.com/schneider/MGN60647","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60647","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H Multi9 miniature circuit breaker, MGN60647, 1 A rated current, C-curve, 4 poles, 50 kA Icu at 250 V DC, EN/IEC 60947-2.","salesMarkdown":"The MGN60647 is a C60H miniature circuit breaker from the Multi9 range, rated 1 A at 50 °C per EN/IEC 60947-2. Four protected poles on a 4P frame give you full isolation on a 3-phase + neutral DC or AC circuit — the suitability-for-isolation marking (per EN/IEC 60947-2) means you can use it as a visible-break disconnect for lockout/tagout. That 50 kA DC figure is unusually high for a 1 A frame — it safely interrupts a hard fault on a battery bank or DC bus without cascading upstream. Snaps onto 35 mm symmetrical DIN rail (EN 60715). Fixed mounting, toggle control, ON/OFF indication on the front. The 4-pole body occupies 8 x 9 mm pitches (72 mm wide). Comb busbar compatible top or bottom — standard for Multi9 distribution boards.","metaTitle":"MGN60647 C60H MCB, 1 A C-Curve, 4P, 50 kA DC Breaking Capaci","metaDescription":"Schneider Electric MGN60647 C60H miniature circuit breaker, 1 A rated, C-curve, 4-pole, 50 kA Icu at 250 V DC. Active production, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"1 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/172b050b2063a840d34e3ceaa3c9b2ce.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60647/c60-circuit-breaker-c60h-4p-1a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60647/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60647 at 250 V DC?","answer":"50 kA Icu at 250 V DC phase-to-phase per EN/IEC 60947-2. The Ics at that voltage is also 50 kA at 100 %."},{"question":"What compliance standards does MGN60647 meet?","answer":"Designed and tested to EN/IEC 60947-2, pollution degree 3. The suitability-for-isolation marking and IP20 protection are part of that certification."},{"question":"Where can I buy MGN60647?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60647","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60647 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}