{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60648","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60648","canonicalUrl":"https://aoctrl.com/schneider/MGN60648","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60648","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60648 miniature circuit breaker, 4-pole, 2 A rated current, C-curve, 30 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The MGN60648 is a Schneider Electric C60H miniature circuit breaker from the Multi9 range, rated 2 A at 50 °C with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20 %). The 4-pole configuration with 4 protected poles makes it a straight choice for three-phase plus neutral distribution circuits where you need coordinated overcurrent and short-circuit protection on all poles. That is a high-capacity rating for a 2 A frame, so it is sized for installations with substantial upstream fault current, not a lightly braked subpanel. That is a real-world durability figure: if you are coordinating selectivity in a panel where a downstream fault might hit 15 kA, this breaker survives the event and stays in service. At 250 V DC the Icu jumps to 50 kA, which is unusually high for a DC-rated MCB — it handles the arc extinction challenge of DC circuits where there is no natural zero-crossing. Rated operational voltage spans 240 V AC phase-to-phase, 415 V AC phase-to-phase, 440 V AC, and 250 V DC. The 72 mm width (8 x 9 mm pitches) for a 4-pole breaker is the expected footprint; it occupies four module spaces. The IP20 finger-safe terminals are fine for enclosed distribution boards; no washdown rating here. The toggle control with ON/OFF indication gives a clear visual state for commissioning and troubleshooting. The C60H series is the high-breaking-capacity variant of the C60 family. If you are auditing an installed base or filling a spare, the Multi9 range is a well-established platform with broad comb-busbar and distribution-block compatibility (top or bottom feed). The separate earth-leakage protection block option means you can add RCD functionality without replacing the breaker.","metaTitle":"Schneider Electric MGN60648 C60H MCB, 2A C-Curve 4P, 30kA","metaDescription":"Schneider Electric MGN60648 C60H miniature circuit breaker, 2 A rated, C-curve, 4-pole, 30 kA breaking capacity at 240 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"2 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad6dbbb3f0e6c80261662a3f27372a7b.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60648/c60-circuit-breaker-c60h-4p-2a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60648/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60648?","answer":"The MGN60648 has a rated breaking capacity (Icu) of 30 kA at 240 V AC phase-to-phase, 15 kA at 415 V AC, 10 kA at 440 V AC, and 50 kA at 250 V DC, all per EN/IEC 60947-2."},{"question":"What is the rated current and curve of MGN60648?","answer":"Rated current is 2 A at 50 °C with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20 %)."},{"question":"Where can I buy MGN60648 and how is it quoted?","answer":"The MGN60648 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does MGN60648 comply with?","answer":"It complies with EN/IEC 60947-2, utilisation category A, and is suitable for isolation per that standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60648","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60648 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}