{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60653","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60653","canonicalUrl":"https://aoctrl.com/schneider/MGN60653","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60653","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H Multi9 series, MGN60653 miniature circuit-breaker (MCB), 4-pole, 16 A rated current, C-curve, 30 kA breaking capacity at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The MGN60653 is a Schneider Electric C60H miniature circuit-breaker from the Multi9 range, designed for distribution applications. Breaking capacity reaches 30 kA Icu at 240 V AC phase-to-phase under EN/IEC 60947-2, and 50 kA Icu at 250 V DC — figures that give selectivity headroom in a sub-distribution board fed by a larger upstream breaker. IP20 finger-safe protection suits enclosed panel use; the toggle control provides local ON/OFF indication and a contact-position indicator confirms isolation status — important for lockout-tagout verification. ## Electrical performance and duty Rated operational voltage (Ue) covers 240/415/440 V AC 50/60 Hz and 250 V DC. The service breaking capacity (Ics) is 50% of Icu at AC voltages — 15 kA at 240 V AC, 7.5 kA at 415 V AC, 5 kA at 440 V AC — and 100% at 250 V DC (50 kA). That 100% DC rating means the breaker clears its full interrupting rating repeatedly without derating, which is rare for an MCB in DC circuits. Magnetic tripping threshold is 8.5 x In ±20%, so for the 16 A version the instantaneous trip picks up between roughly 109 A and 163 A.","metaTitle":"MGN60653 C60H MCB, 16 A C-curve, 4P, 30 kA","metaDescription":"MGN60653 Schneider C60H miniature circuit-breaker, 16 A, C-curve, 4-pole, 30 kA Icu at 240 V AC. EN/IEC 60947-2. Sourced to order, quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"16 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/45edca0fef670192439a5d1a505e8bfd.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60653/c60-circuit-breaker-c60h-4p-16a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60653/alternatives.json"},"ai":{"faq":[{"question":"Who supplies MGN60653 and how is it quoted for volume purchases?","answer":"MGN60653 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your target quantity and delivery window."},{"question":"What is the breaking capacity of MGN60653 at 240 V AC?","answer":"The MGN60653 has a rated ultimate breaking capacity (Icu) of 30 kA at 240 V AC 50/60 Hz phase-to-phase, conforming to EN/IEC 60947-2."},{"question":"What compliance standards does MGN60653 meet?","answer":"MGN60653 is certified to EN/IEC 60947-2 for utilization category A, and is marked suitable for isolation. It carries IP20 finger-safe protection and is rated for pollution degree 3 industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60653","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60653 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}