{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60654","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60654","canonicalUrl":"https://aoctrl.com/schneider/MGN60654","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60654","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, MGN60654 miniature circuit breaker, 20 A, C-curve, 4 poles, 30 kA Icu at 240 V AC, 50 kA Icu at 250 V DC.","salesMarkdown":"The MGN60654 is a C60H miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2 with a C-curve (magnetic trip at 8.5 x In ±20 %). The 4-pole configuration and 30 kA Icu at 240 V AC — 50 kA Icu at 250 V DC — mean it handles high fault currents typical in distribution panels fed by transformers or large UPS systems. Snaps onto 35 mm symmetrical DIN rail, 72 mm wide, 8 module pitches. ## Selectivity and coordination Rated service breaking capacity (Ics) is 15 kA at 240 V AC (50 % of Icu), 7.5 kA at 415 V AC, and 50 kA at 250 V DC (100 % of Icu). That 100 % Ics at DC is unusual — the breaker clears a DC fault at full rated interrupting capacity without derating, which matters for battery-backed or rectifier-fed DC bus protection. For AC coordination, the 50 % Ics figure means the breaker can be reclosed after a fault at that level; above it, replacement is recommended per EN/IEC 60947-2 Category A. Fixed mounting on 35 mm DIN rail. Tightening torque: 2 N·m on the power circuit. Wire strip length: 14 mm. IP20 finger-safe protection. Earth-leakage protection via a separate Vigi block (not integrated).","metaTitle":"MGN60654 C60H MCB, 20 A C-curve 4P, 30 kA breaking capacity","metaDescription":"MGN60654 C60H miniature circuit breaker, 20 A rated current, C-curve, 4 poles, 30 kA Icu at 240 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"20 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d1b57aff4cd70b0e4acd4fe71448d7.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60654/c60-circuit-breaker-c60h-4p-20-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60654/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for MGN60654?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to MGN60654 in the C60 family?","answer":"Within the C60 range, the C60N variant offers a lower breaking capacity (typically 10–15 kA Icu at 240 V AC) versus the C60H's 30 kA. If your fault current study shows available short-circuit current under 15 kA at the panel, the C60N may be a cost-effective drop-in. Otherwise, the C60H is the correct choice for higher fault duty."},{"question":"What compliance documentation does MGN60654 carry?","answer":"The breaker is certified to EN/IEC 60947-2. It carries CE marking for the European market. For specific RoHS, REACH, or UL documentation, request the compliance package at RFQ time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60654","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60654 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}