{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60656","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60656","canonicalUrl":"https://aoctrl.com/schneider/MGN60656","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60656","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H Multi9 series, MGN60656 miniature circuit breaker, 4-pole, 32 A, C-curve, 50 kA Icu at 250 V DC, EN/IEC 60947-2.","salesMarkdown":"## DC-rated breaking capacity for panel protection The MGN60656 is a C60H miniature circuit breaker from the Multi9 range, rated 32 A at 50 °C with a C-curve trip characteristic. Rated operational voltage covers 240/415/440 V AC phase-to-phase and 250 V DC, so it fits both AC distribution boards and DC switchgear. The 4-pole configuration with thermal-magnetic trip unit gives overcurrent and short-circuit protection on all four poles, with magnetic tripping at 8.5 x In ±20 %. Snaps onto 35 mm symmetrical DIN rail, fixed mounting mode. Occupies 8 x 9 mm pitches (72 mm wide), 81 mm tall, 73 mm deep — standard Multi9 footprint that fits existing distribution boards without re-spacing. IP20 finger-safe terminals; tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors. Toggle switch with ON/OFF indication and contact position indicator. Compatible with comb busbars and distribution blocks on top or bottom. Pollution degree 3, utilisation category A, suitable for isolation. Electrical durability rated 10,000 cycles; mechanical durability 20,000 cycles.","metaTitle":"MGN60656 C60H MCB 32A 4P C-Curve DC, 50 kA at 250 V DC","metaDescription":"MGN60656 C60H miniature circuit breaker, 32 A, 4-pole, C-curve, 50 kA Icu at 250 V DC. EN/IEC 60947-2. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2","Device short name":"C60H","Poles description":"4P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"32 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc70727738c9bb66843e64ccb800396e.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60656/c60-circuit-breaker-c60h-4p-32-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60656/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60656 at 250 V DC?","answer":"50 kA Icu at 250 V DC phase-to-phase conforming to EN/IEC 60947-2. At 240 V AC it is 30 kA Icu, at 415 V AC 15 kA Icu, and at 440 V AC 10 kA Icu."},{"question":"Where can I buy MGN60656?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the rated current of MGN60656?","answer":"32 A at 50 °C conforming to EN/IEC 60947-2."},{"question":"What is the depth of MGN60656?","answer":"73 mm."},{"question":"What standards does MGN60656 comply with?","answer":"EN/IEC 60947-2 for low-voltage switchgear and controlgear, pollution degree 3, suitable for isolation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60656","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60656 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}