{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60892","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60892","canonicalUrl":"https://aoctrl.com/schneider/MGN60892","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60892","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N, MGN60892, 3-pole miniature circuit-breaker, 6 A, C curve, 20 kA Icu at 240 V AC, thermal-magnetic trip, 35 mm DIN rail mount.","salesMarkdown":"The MGN60892 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range, rated 6 A at 50 °C per EN/IEC 60947-2 with a C curve. Three protected poles, thermal-magnetic trip unit, toggle control with ON/OFF indication and a contact position indicator. Breaking capacity hits 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V. Service breaking capacity (Ics) is 75 % of those figures — 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. Magnetic tripping threshold is 8.5 x In ± 20 %. Pollution degree 3 rated. Dimensions: 81 mm high, 54 mm wide, 73 mm deep. 6 module pitches (9 mm each). IP20 finger protection. Earth-leakage protection requires a separate block — no holes in the box for that function, but the breaker is comb busbar compatible top or bottom. The C curve (magnetic trip at 8.5 x In ± 20 %) means this breaker handles moderate inrush — typical for motor starters, small transformers, and lighting banks in distribution panels. The 6 A rating at 50 °C is the continuous current; no derate needed at that ambient, but above 50 °C the thermal element shifts. Ics at 75 % (15 kA) is the rating for repeated fault clearing without replacement. For a 3-pole DC network application, verify the DC voltage rating against your system; the listed ratings are AC phase-to-phase. ## Panel integration Snaps onto 35 mm symmetrical DIN rail — standard for any enclosure. 6 module pitches (54 mm wide) means it occupies six 9 mm slots on the rail. Comb busbar compatible top or bottom, so daisy-chaining multiple breakers in a row is straightforward.","metaTitle":"MGN60892 C60N MCB, 3P 6A C-Curve, 20 kA, Multi9","metaDescription":"MGN60892 C60N miniature circuit-breaker, 3 poles, 6 A rated current, C curve, 20 kA breaking capacity at 240 V AC. EN/IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"6 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b858933c90bf18ce4e93e729f92e7304.pdf","sourceUrl":"https://www.se.com/th/en/product/MGN60892/c60-circuit-breaker-c60n-3p-6a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60892/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for MGN60892?","answer":"The MGN60892 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"What is the closest alternative to MGN60892 in the Multi9 family?","answer":"Within the C60N range, the closest sibling is a different ampere rating or pole count — same C curve, same breaking capacity class, same DIN-rail footprint. The MGN60892 is a 3-pole 6 A unit; a 10 A or 16 A variant in the same C60N 3-pole format would be the direct swap if the load requires higher current. No pin-compatible alternative exists outside the Multi9 C60N series for a drop-in replacement."},{"question":"What compliance documentation does MGN60892 carry?","answer":"The MGN60892 is certified to EN/IEC 60947-2. The evidence does not list RoHS, REACH, UL, or CSA marks specifically — verify with the manufacturer's declaration for your jurisdiction. The standard itself covers miniature circuit-breakers for industrial applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60892","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60892 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}