{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60893","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60893","canonicalUrl":"https://aoctrl.com/schneider/MGN60893","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60893","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N miniature circuit-breaker, MGN60893, 3P, C-curve, 10 A, 20 kA Icu at 240 V AC, thermal-magnetic trip, DIN-rail mount.","salesMarkdown":"The MGN60893 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range, rated 10 A at 50 °C with a C trip curve and 3 poles. It breaks 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2. The 3-pole block takes 6 module pitches (54 mm wide), so it fits a standard 6-M slot in a distribution board. Torque to 2 N·m on the power circuit. Strip 14 mm of insulation. Built to EN/IEC 60947-2, Category A, with pollution degree 3. Suitable for isolation (contact position indicator on the toggle). Service breaking capacity (Ics) is 75% of Icu: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. Electrical durability 10,000 cycles, mechanical 20,000 cycles. Earth-leakage protection via a separate block.","metaTitle":"MGN60893 C60N MCB, 3P C-curve 10 A, 20 kA breaking","metaDescription":"MGN60893 C60N miniature circuit-breaker, 3-pole, C-curve, 10 A rated current, 20 kA Icu at 240 V AC. EN/IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"10 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9f34110f5cd4fe3a7733ad6e133843e.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60893/c60-circuit-breaker-c60n-3p-10a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60893/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60893 and get a price?","answer":"We source the MGN60893 to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ through this listing."},{"question":"What is the breaking capacity of MGN60893?","answer":"The MGN60893 has a rated breaking capacity (Icu) of 20 kA at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2."},{"question":"What is the closest alternative to MGN60893 in the same family?","answer":"Within the C60 range, the main difference is the curve code — this is a C curve. A B-curve sibling would trip magnetically at a lower threshold (3.2–4.8 x In), better for resistive loads or long cable runs; a D-curve sibling trips at 10–14 x In, suited for high-inrush loads like large motors or transformers. The physical footprint and breaking capacities are otherwise identical."},{"question":"What compliance documentation does Schneider provide for MGN60893?","answer":"The MGN60893 is certified to EN/IEC 60947-2. Schneider Electric typically provides a Declaration of Conformity (CE) and may supply UL/CSA documentation depending on the variant. Specific documentation is available on request at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60893","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60893 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}