{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60894","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60894","canonicalUrl":"https://aoctrl.com/schneider/MGN60894","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60894","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 miniature circuit breaker, MGN60894, 16 A rated current, C curve, 3 poles, 20 kA breaking capacity at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"## Panel-builder commissioning notes The Schneider Electric MGN60894 is a C60N miniature circuit breaker from the Multi9 range, rated 16 A with a C curve and 3 protected poles. The 20 kA Icu at 240 V AC phase-to-phase (EN/IEC 60947-2) gives it enough interrupting capacity for most distribution subfeeds; the service breaking capacity Ics is 15 kA (75 %) at the same voltage, meaning it can reclose after a fault at that level without immediate replacement. Thermal-magnetic trip technology with a magnetic threshold of 8.5 x In (±20 %) handles motor inrush and lighting loads cleanly. ## DIN rail integration Top or bottom feed is supported, with comb busbar and distribution block compatibility. The toggle actuator provides local ON/OFF indication. Earth-leakage protection requires a separate block — not integrated.","metaTitle":"Schneider Electric MGN60894 C60N MCB, 16 A, C Curve, 3P, 20","metaDescription":"Schneider Electric MGN60894 C60N miniature circuit breaker, 16 A rated current, C curve, 3 poles, 20 kA breaking capacity at 240 V AC. EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","title":"MGN60894","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","description":"C60 - circuit breaker - C60N - 3P - 16A - C curve","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"16 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/994fc54a37e89f207675fb0dcf436c79.pdf","sourceUrl":"https://www.se.com/th/en/product/MGN60894/c60-circuit-breaker-c60n-3p-16a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60894/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60894?","answer":"The MGN60894 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of MGN60894?","answer":"The MGN60894 has a breaking capacity (Icu) of 20 kA at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2."},{"question":"What standards does MGN60894 comply with?","answer":"The MGN60894 complies with EN/IEC 60947-2 and is suitable for isolation per that standard. Pollution degree 3 is rated."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60894","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60894 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}