{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60896","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60896","canonicalUrl":"https://aoctrl.com/schneider/MGN60896","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60896","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 miniature circuit breaker, 25 A, C curve, 20 kA Icu at 240 V AC, 3 poles, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The MGN60896 is a C60N miniature circuit breaker from the Multi9 range, rated 25 A at 50 °C with a C curve (magnetic trip at 8.5 x In ±20 %). The 3-pole configuration protects three phases, and the thermal-magnetic trip unit handles both overload (thermal) and short-circuit (magnetic) events in a single device. This is a distribution MCB for final subcircuit protection in commercial and industrial panels. The C curve suits moderate inrush loads — lighting banks, small motor starters, control transformers — where the magnetic trip at 8.5 x In avoids nuisance tripping on startup while still clearing hard faults. Category A (no intentional short-time delay) means it trips instantaneously on magnetic pickup; coordination with upstream devices depends on the I²t let-through. IP20 finger protection is standard for enclosed panel mounting. The toggle switch provides local ON/OFF indication, and the contact position indicator confirms the state visually.","metaTitle":"MGN60896 C60N MCB, 25 A, C Curve, 20 kA, 3P","metaDescription":"MGN60896 C60N miniature circuit breaker, 25 A rated current, C curve, 20 kA breaking capacity at 240 V AC, 3 poles, DIN rail mount. EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"3P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"25 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3ff93678bce9d84d3c817dc1c8137b8a.pdf","sourceUrl":"https://www.se.com/sg/en/product/MGN60896/c60-circuit-breaker-c60n-3p-25a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60896/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60896?","answer":"The MGN60896 has a rated breaking capacity (Icu) of 20 kA at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of Icu at each voltage level."},{"question":"What is the closest alternative to MGN60896 in the same family?","answer":"Within the C60N range, the closest peer is the same 25 A, C-curve, 3-pole variant with a different breaking capacity tier — the C60H (higher Icu) or C60L (lower Icu). The MGN60896 sits at the standard C60N breaking level (20 kA at 240 V). No pin-compatible drop-in exists with different ratings; the physical footprint (6 module pitches, 54 mm wide) is identical across the C60 series, so swapping between tiers is a straight DIN-rail replacement if the SCCR study allows."},{"question":"How do I get pricing and availability for MGN60896?","answer":"Submit an RFQ through the storefront. The part is sourced to order via independent distribution; current pricing and lead time are confirmed at quote time against your quantity and delivery window."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60896","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60896 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}