{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60898","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60898","canonicalUrl":"https://aoctrl.com/schneider/MGN60898","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60898","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 miniature circuit breaker, MGN60898, 40 A, 3 poles, C-curve, 20 kA breaking capacity at 240 V AC, thermal-magnetic trip, 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric MGN60898 is a C60N miniature circuit breaker from the Multi9 range, rated 40 A at 50 °C with a C-curve trip characteristic. The 3-pole footprint takes 6 module pitches (54 mm wide), so it occupies three adjacent slots on the rail. Tunnel terminals accept 1.5 to 35 mm² rigid or flexible wire; strip length is 14 mm, torque to 3.5 N·m. IP20 finger-safe front, pollution degree 3 rated, so it handles the dusty, humid environment inside a typical industrial cabinet without derating. Rated operational voltage is 440 V AC 50/60 Hz, with service breaking capacity (Ics) at 75 % of Icu: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. Magnetic tripping threshold is 8.5 x In ±20 % — so on a 40 A breaker, the instantaneous magnetic trip fires between about 272 A and 408 A. That's a tight window for a C-curve, good for motor-starting inrush without nuisance trips on moderate inductive loads. Electrical endurance is 10,000 cycles; mechanical is 20,000. Suitability for isolation is marked, with a contact position indicator and ON/OFF local signaling.","metaTitle":"Schneider Electric MGN60898 C60N MCB, 40A 3P C-Curve, 20kA","metaDescription":"Schneider Electric MGN60898 C60N miniature circuit breaker, 40A rated, 3 poles, C-curve, 20kA breaking capacity at 240V AC. EN/IEC 60947-2. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"54 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"3P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"40 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1da3eacbd90cc14f89ab9540589df1a.pdf","sourceUrl":"https://www.se.com/th/en/product/MGN60898/c60-circuit-breaker-c60n-3p-40a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60898/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60898?","answer":"20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2."},{"question":"Where can I buy MGN60898?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"What wire size does MGN60898 accept?","answer":"Tunnel terminals accept 1.5 to 35 mm² flexible (with or without cable end) or rigid wire. Strip length 14 mm, torque 3.5 N·m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60898","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60898 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}