{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60901","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60901","canonicalUrl":"https://aoctrl.com/schneider/MGN60901","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60901","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N, MGN60901, miniature circuit breaker, 1 A, C-curve, 4P, 20 kA Icu at 240 V AC, thermal-magnetic, EN/IEC 60947-2.","salesMarkdown":"## C60N 1 A C-curve 4P MCB — panel fit and protection profile The 1 A rating suits low-current loads — control transformers, signal supplies, or lighting circuits drawing under 1 A continuous. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, derating to 10 kA at 415 V and 6 kA at 440 V. The service breaking capacity (Ics) is 75 % of Icu at each voltage level — 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V — meaning the breaker can be reclosed after a fault at those levels without immediate replacement, which matters for selectivity coordination studies. Tighten to 2 N.m. Earth-leakage protection requires a separate block (not integrated).","metaTitle":"MGN60901 C60N MCB, 1 A C-curve 4P, 20 kA breaking capacity","metaDescription":"Schneider Electric MGN60901 C60N miniature circuit breaker, 1 A rated current, C-curve, 4 poles, 20 kA Icu at 240 V AC. Active lifecycle, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"1 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3657f0a38ff6b97981026f8afe2ee562.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN60901/c60-circuit-breaker-c60n-4p-1a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60901/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60901?","answer":"The MGN60901 has a breaking capacity of 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2."},{"question":"What is the closest alternative to MGN60901 in the C60 family?","answer":"Within the C60 range, the MGN60901 is a 1 A C-curve 4P unit. A higher-current variant would be needed for loads above 1 A, but the physical footprint and DIN-rail mounting remain identical across the C60N series."},{"question":"What compliance documentation does MGN60901 carry?","answer":"The MGN60901 is certified to EN/IEC 60947-2. It carries IP20 protection and is suitable for isolation per that standard. Specific RoHS/REACH/UL declarations are available from the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60901","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60901 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}