{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60902","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60902","canonicalUrl":"https://aoctrl.com/schneider/MGN60902","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60902","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60N, MGN60902, miniature circuit-breaker, 4P, C-curve 2 A, 20 kA Icu at 240 V AC, thermal-magnetic, DIN rail mount.","salesMarkdown":"The Schneider Electric MGN60902 is a C60N miniature circuit-breaker from the Multi9 range — a 4-pole, C-curve unit rated 2 A at 50 °C (EN/IEC 60947-2). The C-curve magnetic trip fires at 8.5 x In (±20 %), which means it tolerates motor inrush or capacitor charging surges better than a B-curve, but still clears fast enough for general branch-circuit protection. Snaps onto 35 mm symmetrical DIN rail. Takes 8 module pitches at 9 mm each — that is 72 mm wide, 81 mm tall, 73 mm deep. IP20 finger-safe front, pollution degree 3 rated, so it is fine inside a standard enclosed panel.","metaTitle":"MGN60902 C60N MCB, 4P, C-curve 2 A, 20 kA","metaDescription":"MGN60902 C60N miniature circuit-breaker, 4 poles, C-curve 2 A, 20 kA Icu at 240 V AC. Active production, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"2 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/81d7ea685cfa606b525c42ed7f22a7c1.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60902/c60-circuit-breaker-c60n-4p-2a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60902/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60902?","answer":"20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of those values."},{"question":"What is the closest alternative to MGN60902 in the same family?","answer":"Within the C60 range, the C60H (higher breaking capacity) and C60L (higher still) share the same footprint and terminal layout. The C60N is the standard-duty variant; if you need more fault-clearing margin without changing the DIN-rail layout, the C60H is the natural step-up."},{"question":"How do I get pricing and availability for MGN60902?","answer":"Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60902","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60902 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}