{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60904","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60904","canonicalUrl":"https://aoctrl.com/schneider/MGN60904","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60904","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60904, 4-pole, C-curve, 4 A rated current, 20 kA breaking capacity at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The MGN60904 is a 4-pole C60N miniature circuit-breaker from the Multi9 range, rated 4 A with a C trip curve. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. Rated operational voltage is 440 V AC 50/60 Hz, so it covers standard 400/415 V three-phase panels. The thermal-magnetic trip unit handles overloads thermally and short-circuits magnetically — no electronics to fail. ## Mounting and integration — DIN rail, 8-pitch footprint The 4-pole body takes 8 x 9 mm pitches (72 mm wide), so plan for 72 mm of rail space plus finger-duct clearance on each side. Strip length 14 mm. IP20 rated — suitable for enclosed panel use only, not washdown or outdoor. Ambient operating range -30…70 °C, storage -40…80 °C.","metaTitle":"MGN60904 C60N MCB 4P C-Curve 4A 20kA, Multi9","metaDescription":"MGN60904 C60N miniature circuit-breaker, 4-pole C-curve 4A, 20kA breaking capacity at 240V AC. EN/IEC 60947-2. DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"4P","Tightening torque":"Power circuit: 2 N.m","Device application":"Distribution","[In] rated current":"4 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7fdc9e08e15c79b45cb5ae7fbc8c0ac0.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60904/c60-circuit-breaker-c60n-4p-4a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60904/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGN60904?","answer":"The MGN60904 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of MGN60904?","answer":"20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2."},{"question":"What is the closest alternative to MGN60904 in the C60 family?","answer":"Within the C60 range, the main variant is the C60H (higher breaking capacity — 25 kA at 415 V) versus the C60N here at 10 kA at 415 V. The C60L offers 15 kA at 415 V. All share the same 4-pole C-curve 4 A thermal-magnetic trip and DIN-rail footprint, so the choice is driven by the required fault level at the installation point."},{"question":"What compliance documentation does Schneider provide for MGN60904?","answer":"The MGN60904 is certified to EN/IEC 60947-2. Standard documentation includes the manufacturer's declaration of conformity and the product datasheet. Specific RoHS or REACH declarations are available from Schneider Electric upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60904","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60904 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}