{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN60913","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN60913","canonicalUrl":"https://aoctrl.com/schneider/MGN60913","factsUrl":"https://aoctrl.com/api/mcp/products/MGN60913","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60N Multi9 miniature circuit breaker, MGN60913, 4-pole, 63 A, C curve, 20 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The MGN60913 is a C60N miniature circuit breaker from the Multi9 range, rated 63 A at 50 °C per EN/IEC 60947-2. The 4-pole configuration protects all phases plus neutral in a single 72 mm wide package, occupying 8 x 9 mm pitch spaces on a 35 mm DIN rail. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, derating to 10 kA at 415 V and 6 kA at 440 V. The service breaking capacity Ics is 75 % of those values — 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. That means after clearing a fault at the Ics level, the breaker remains functional for continued service, not just a one-shot isolation event. For a distribution board with a 22 kA prospective fault current upstream, this breaker needs a current-limiting upstream device to stay within its rating. The 72 mm width (8 x 9 mm pitches) fits standard distribution board grids. Tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors (with or without ferrules); strip length is 14 mm, torque to 3.5 N·m. The 63 A rating is at 50 °C; expect derating above that ambient. The toggle provides local ON/OFF indication and a contact position indicator for visual confirmation of isolation state.","metaTitle":"MGN60913 C60N MCB, 4P, 63 A, C Curve, 20 kA","metaDescription":"MGN60913 C60N miniature circuit breaker, 4 poles, 63 A rated current, C curve, 20 kA breaking capacity at 240 V AC. Active production, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC","Product name":"C60","Mounting mode":"Fixed","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Range of product":"C60","Breaking capacity":"20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2","Device short name":"C60N","Poles description":"4P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"63 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles conforming to EN/IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid","IP degree of protection":"IP20 conforming to EN/IEC 60947-2","Magnetic tripping limit":"8.5 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ue] rated operational voltage":"440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0a38f5465740e4cf0483ea7744d35a7e.pdf","sourceUrl":"https://www.se.com/vn/en/product/MGN60913/c60-circuit-breaker-c60n-4p-63a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN60913/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN60913?","answer":"The MGN60913 has a breaking capacity of 20 kA Icu at 240 V AC, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. The service breaking capacity Ics is 75 % of those values."},{"question":"What terminals does MGN60913 accept?","answer":"Tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors, with or without ferrules. Strip length is 14 mm, tightening torque 3.5 N·m."},{"question":"Where can I buy MGN60913?","answer":"The MGN60913 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN60913","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN60913 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}