{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN61330","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN61330","canonicalUrl":"https://aoctrl.com/schneider/MGN61330","factsUrl":"https://aoctrl.com/api/mcp/products/MGN61330","rawCanonicalId":null},"summary":{"shortDescription":"Schneider MGN61330 Molded Case Circuit Breakers — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The MGN61330 is a Schneider Multi9 C60 molded case circuit breaker with 3 poles, rated 10 A continuous current and 10 kA breaking capacity (Icu) at 277 V AC, 60 Hz. This part is in active production. ## Lifecycle & availability Schneider lists the MGN61330 as an active, current-production item.","metaTitle":"Schneider MGN61330 Multi9 C60 MCCB, 3-pole, 10 A, 10 kA, 277 V AC","metaDescription":"Schneider Multi9 C60 MGN61330 molded case circuit breaker, 3-pole, 10 A, 10 kA breaking capacity, 277 V AC, 60 Hz, DIN-rail, IP20. Active, RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Gray","Depth":"2.7 in (68.7 mm)","Range":"Multi9","Width":"2.1 in (54 mm)","Height":"5.6 in (141 mm)","Category":"US10DE200915","Standards":"GB 14048.2 EN/IEC 60947-2 UL 489 CSA C22.2 No 5","Curve code":"C","9 Mm Pitches":"6","Control Type":"Toggle","Network type":"AC","Product name":"Multi9 C60","Mounting Mode":"Clip-on","Tropicalisation":"2 IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 EN/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting Support":"DIN rail","Pollution degree":"3 EN/IEC 60947-2","Breaking capacity":"10 kA AIR 480Y/277 V AC UL 489 10 kA AIR 480Y/277 V AC CSA C22.2 No 5.2 10 kA Icu 480Y/277 V AC EN/IEC 60947-2 10 kA Icu 480Y/277 V AC GB 14048.2","Device short name":"C60 UL489","Network Frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % 131 °F (55 °C)","Tightening torque":"7.08 lbf.in (0.8 N.m) top or bottom","Device Application":"Distribution","Line Rated Current":"10 A 77 °F (25 °C)","Operating altitude":"6561.68 ft (2000 m)","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Nbr. of units in pkg.":"1","Connections - terminals":"Tunnel type terminal top or bottom) - 1 0.002...0.002 in² (1...1.5 mm²) AWG 18...AWG 16) - rigid Tunnel type terminal top or bottom) - 2 0.002...0.002 in² (1...1.5 mm²) AWG 18...AWG 16) - rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"8.5 x In +/- 20 % AC","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or Component Type":"Miniature circuit-breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC EN/IEC 60947-2","[Ue] rated operational voltage":"480Y/277 V AC","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-22...158 °F (-30...70 °C)","[Uimp] rated impulse withstand voltage":"6 kVEN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$98.60","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/16af72bc72d8375c04e89133752e1ea9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN61330/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN61330","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN61330 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}