{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN61822","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN61822","canonicalUrl":"https://aoctrl.com/schneider/MGN61822","factsUrl":"https://aoctrl.com/api/mcp/products/MGN61822","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H-DC miniature circuit breaker, MGN61822, 2-pole, B curve, 50 A rated, DC network, 20 kA breaking capacity at 250 V DC, DIN rail mount.","salesMarkdown":"## DC-rated miniature circuit breaker for distribution panels The MGN61822 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker rated 50 A at 50 °C per EN/IEC 60947-2, with a B curve and magnetic tripping at 5.5 x In ±20 % DC. It is a 2-pole device (2P) designed for DC networks up to 500 V DC operational voltage. Breaking capacity reaches 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC — all conforming to EN/IEC 60947-2. Snap-on mounting to DIN rail, occupying 4 modules of 9 mm pitch (36 mm width). The IP20 finger-safe front and IP40 modular enclosure suit enclosed distribution boards. Tunnel terminals accept 1 to 35 mm² rigid stranded (AWG 18 to AWG 2) or up to 25 mm² flexible with ferrule. Strip length is 14 mm; tightening torque 3.5 N.m. Up to three 4 mm² cables can share one terminal. Padlockable toggle provides ON/OFF indication and contact position indicator for isolation — the breaker is certified for isolation per EN/IEC 60947-2.","metaTitle":"MGN61822 Multi9 C60H-DC MCB, 50 A, 2P, B Curve, DC","metaDescription":"MGN61822 Multi9 C60H-DC miniature circuit breaker, 50 A rated, 2-pole, B curve, DC rated to 500 V. Breaking capacity 20 kA at 250 V DC. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Colour":"Grey","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC","Product name":"Multi9 C60H-DC","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-2","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN 60947-2","Breaking capacity":"20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2","Device short name":"C60H-DC","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"50 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"3000 cycles L/R = 2 ms","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom)1...35 mm² (AWG 18...AWG 2) - rigid stranded Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 4 mm² (AWG 6) - flexible stranded","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5.5 x In +/- 20 % DC","Earth-leakage protection":"Without","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V DC conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"250 V DC 500 V DC 220 V DC 440 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ff5c1a057a5fa60c84d3be2a96d4313e.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN61822/multi9-c60hdc-mcb-2p-50-a-b-curve-500-v-6-ka/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN61822/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of MGN61822 at different DC voltages?","answer":"20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2."},{"question":"What standards does MGN61822 comply with?","answer":"It conforms to EN/IEC 60947-2 for miniature circuit breakers, with pollution degree 3 and tropicalisation class 2 per IEC 60068-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN61822","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN61822 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}