{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGN61884","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGN61884","canonicalUrl":"https://aoctrl.com/schneider/MGN61884","factsUrl":"https://aoctrl.com/api/mcp/products/MGN61884","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H-DC, 2-pole DC miniature circuit breaker, 16 A rated, K-curve, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.","salesMarkdown":"## DC circuit protection for distribution panels The MGN61884 is a 2-pole DC miniature circuit breaker from the Schneider Electric Multi9 C60H-DC series, rated 16 A at 50 °C with a K-curve trip characteristic. Its magnetic tripping limit is set at 12 x In (±20 %) for DC circuits, meaning it handles moderate inrush without nuisance trips while still clearing hard faults fast — a good fit for DC distribution loads like battery banks, UPS outputs, or solar combiner boxes where the load current is steady but fault current can spike. Breaking capacity is 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC per EN/IEC 60947-2. Strip length is 14 mm. The IP20 finger-safe front and IP40 modular enclosure keep panel builders compliant during commissioning.","metaTitle":"MGN61884 Multi9 C60H-DC MCB, 2P 16A K-curve DC, 20 kA","metaDescription":"MGN61884 is a 2-pole DC miniature circuit breaker, 16 A rated, K-curve, 20 kA breaking capacity at 250 V DC. Active production, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Colour":"Grey","Height":"81 mm","Standards":"EN/IEC 60947-2","Curve code":"K","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC","Product name":"Multi9 C60H-DC","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-2","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN 60947-2","Breaking capacity":"20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2","Device short name":"C60H-DC","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A at 50 °C conforming to EN/IEC 60947-2","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"3000 cycles L/R = 2 ms","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 % DC","Earth-leakage protection":"Without","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V DC conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"250 V DC 500 V DC 220 V DC 440 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/484e421f1264822be3b0798914cc0500.pdf","sourceUrl":"https://www.se.com/be/en/product/MGN61884/multi9-c60hdc-mcb-2p-16-a-k-curve-500-v-6-ka/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGN61884/alternatives.json"},"ai":{"faq":[{"question":"What is MGN61884's breaking capacity at 250 V DC?","answer":"20 kA Icu at 250 V DC per EN/IEC 60947-2. It also carries 20 kA at 220 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC."},{"question":"Where can I buy MGN61884?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote."},{"question":"What standards does MGN61884 comply with?","answer":"It is designed and tested to EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear circuit breakers. Pollution degree 3 per EN 60947-2, tropicalisation class 2 per IEC 60068-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGN61884","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGN61884 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}