{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP0252L2N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP0252L2N","canonicalUrl":"https://aoctrl.com/schneider/MGP0252L2N","factsUrl":"https://aoctrl.com/api/mcp/products/MGP0252L2N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0252L2N, 1P+N, 25 A at 40 °C, 230 V AC, 25 kA Icu at 415 V AC, TM-D trip unit, LI protection.","salesMarkdown":"The Schneider Electric MGP0252L2N is a PowerPacT 4 molded case circuit breaker (MCCB) rated 25 A at 40 °C, 1P+N (L2-N), 230 V AC 50/60 Hz, with a TM-D thermal-magnetic trip unit providing LI protection (overload and short-circuit). It carries a 25 kA Icu and Ics at 415 V AC, Category A utilization, and is suitable for isolation per BS EN 60947-2. The unit is panel-mounted, fits a 2-module (35 mm) footprint, and can be mounted horizontally or vertically. The 8 kV impulse withstand voltage (Uimp) means it handles transient surges common in industrial panels without flashover. The 750 V rated insulation voltage (Ui) gives headroom for the internal isolation path. The 20000-cycle mechanical durability and 20000-cycle electrical durability at rated current give a sense of the service life under normal switching — though in distribution duty, it's mostly sitting closed. This is a distribution-circuit breaker — it protects branch circuits in panelboards, subpanels, or directly on a backplate in a control cabinet. The 1P+N configuration (switching the line, monitoring neutral) is typical for single-phase loads in commercial or light industrial distribution. The panel-mount form factor and 2-module width (35 mm) mean it fits standard DIN-rail or backplate layouts, though it's not a snap-on DIN rail breaker — it's bolted to the backplate.","metaTitle":"Schneider Electric MGP0252L2N PowerPacT 4 MCCB, 25 A, 1P+N,","metaDescription":"Schneider Electric MGP0252L2N PowerPacT 4 molded case circuit breaker, 25 A at 40 °C, 1P+N, 230 V AC, 25 kA Icu at 415 V AC. Obsolete; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Standards":"BS EN 60947-2","Control type":"Toggle","Trip unit name":"TM-D","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Mounting support":"Backplate","Phase connection":"L2 - N","Range of product":"PowerPacT 4","Trip unit rating":"25 A at 40 °C","Mounting position":"Horizontal and vertical","Number of modules":"2 module(s)35 mm","Poles description":"1P + N","Device application":"Distribution","[In] rated current":"25 A at 40 °C","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 277 V In/2 10000 cycles at 277 V In","Mechanical durability":"20000 cycles","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to BS EN 60947-2","Circuit breaker mounting mode":"Panel-mounted","[Ui] rated insulation voltage":"750 V","Trip unit protection functions":"LI","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Thermal protection adjustment range":"25 A","[Uimp] rated impulse withstand voltage":"8 kV","[Ics] rated service short-circuit breaking capacity":"25 kA at 415 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"25 kA Icu at 415 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0f62e8164c8c2add6aa8d279aec2fac6.pdf","sourceUrl":"https://www.se.com/uk/en/product/MGP0252L2N/powerpact-4-molded-case-circuit-breaker-2p-25a-230-v-l1-n/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGP0252L2N/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the MGP0252L2N?","answer":"We source the MGP0252L2N to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response."},{"question":"What standards does the MGP0252L2N comply with?","answer":"The MGP0252L2N is listed to BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It is also suitable for isolation per that standard."},{"question":"What is the control type on the MGP0252L2N?","answer":"The control type is Toggle — a manual toggle handle on the front of the breaker for on/off operation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP0252L2N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP0252L2N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}