{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP1004XE2","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP1004XE2","canonicalUrl":"https://aoctrl.com/schneider/MGP1004XE2","factsUrl":"https://aoctrl.com/api/mcp/products/MGP1004XE2","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPacT 4, MGP1004XE2, 4P circuit breaker, MicroLogic 2.2 electronic trip unit, 100 A at 40 °C, 36 kA Icu/Ics at 415 V AC 50/60 Hz, panel-mounted, toggle control.","salesMarkdown":"The MGP1004XE2 is a Schneider Electric PowerPacT 4 4-pole circuit breaker with a MicroLogic 2.2 electronic trip unit, rated 100 A at 40 °C. It's a panel-mounted unit intended for distribution in 250 A or 400/630 A panelboards. The toggle control and backplate mounting support make it a straightforward swap into an existing panel layout — no DIN-rail adapter needed, just bolt it to the backplate and land the conductors. Ics equals Icu here, meaning it can reclose and carry load after a fault at that full rating. That's Category A utilization class, so it's designed for distribution duty where coordination with downstream devices is managed by the trip curve, not for motor-starting applications. The MicroLogic 2.2 electronic trip unit gives you LSoI protection: Long-time (L) with adjustable Ir from 40 to 100 A, Short-time (S) with adjustable Isd from 1.5 to 10 times Ir, instantaneous (I) fixed at 1500 A, and a fixed ground-fault pickup (not present on this unit — it ships without earth-leakage protection). The long-time delay tr and short-time delay tsd are both fixed, so you can't tune the time bands; selectivity relies on the adjustable pickups and the fixed delay characteristics. Mounting position is flexible — horizontal or vertical — so it fits tight enclosures where you need to rotate the breaker to clear other gear. Electrical durability is 50,000 cycles at 440 V at rated current, dropping to 30,000 cycles at 2x In; mechanical durability matches at 50,000 cycles. That's solid for a distribution breaker in a panel that sees regular switching, not just fault protection.","metaTitle":"MGP1004XE2 PowerPacT 4 Circuit Breaker, 100 A, 36 kA","metaDescription":"MGP1004XE2 PowerPacT 4 4P circuit breaker with MicroLogic 2.2 electronic trip unit, 100 A at 40 °C, 36 kA breaking capacity at 415 V AC. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Control type":"Toggle","Trip unit name":"MicroLogic 2.2","lifecycle_stage":"current","Mounting support":"Backplate","Range of product":"PowerPacT 4","Trip unit rating":"100 A at 40 °C","Mounting position":"Horizontal and vertical","Number of modules":"4 module(s)35 mm","Poles description":"4P","Device application":"Distribution","[In] rated current":"100 A at 40 °C","Product destination":"250 A panelboard 400/630 A panelboard","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In","Mechanical durability":"50000 cycles","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to BS EN 60947-2","Circuit breaker mounting mode":"Panel-mounted","[Ui] rated insulation voltage":"800 V","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"415 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"40...100 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"36 kA at 415 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"36 kA Icu at 415 V AC 50/60 Hz","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3cb2eef5680341d8b00b4b873c8c5f45.pdf","sourceUrl":"https://www.se.com/uk/en/product/MGP1004XE2/ptccbodaphotointegration/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGP1004XE2/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGP1004XE2 and how do I get a price?","answer":"MGP1004XE2 is sourced to order against an RFQ through independent distribution. Submit an RFQ with your quantity and target timeline; availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of MGP1004XE2?","answer":"It is a 4-pole, 100 A at 40 °C circuit breaker with a MicroLogic 2.2 electronic trip unit, 36 kA Icu/Ics breaking capacity at 415 V AC, 800 V rated insulation voltage, and 8 kV impulse withstand. Protection functions are LSoI with adjustable long-time and short-time pickups."},{"question":"What is MGP1004XE2's control type?","answer":"The control type is Toggle — a manual handle on the front of the breaker for on/off/tripped indication."},{"question":"What trip unit does MGP1004XE2 use?","answer":"It uses a MicroLogic 2.2 electronic trip unit with LSoI protection functions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP1004XE2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP1004XE2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}