{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP2504X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP2504X","canonicalUrl":"https://aoctrl.com/schneider/MGP2504X","factsUrl":"https://aoctrl.com/api/mcp/products/MGP2504X","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPacT 4, molded case circuit breaker, 4-pole, 250 A, 415 V AC, 36 kA Icu, TM-D trip unit, toggle control, backplate mount.","salesMarkdown":"The MGP2504X is a 4-pole (3P+N) PowerPacT 4 molded case circuit breaker rated 250 A at 40 °C, with a TM-D thermal-magnetic trip unit providing LI protection — thermal overload (L) and magnetic short-circuit (I). It is designed for distribution in 250 A or 400/630 A panelboards, panel-mounted on a backplate, and can be installed horizontally or vertically. ## Breaking capacity and isolation Rated ultimate short-circuit breaking capacity (Icu) is 36 kA at 415 V AC 50/60 Hz, with the same 36 kA service breaking capacity (Ics). The breaker is suitable for isolation per BS EN 60947-2, meaning it provides a visible disconnect gap when open. ## Lifecycle reality — obsolete, not orphaned Schneider Electric lists the MGP2504X as obsolete. No official successor order code is published in the available records. ## Durability and adjustment range Thermal protection adjustment covers 175 to 250 A. Electrical durability is rated at 20,000 cycles at 440 V at rated current, and 10,000 cycles at 440 V at twice rated current. The toggle control is manual; no earth-leakage protection is integrated.","metaTitle":"MGP2504X PowerPacT 4 MCCB, 250 A, 36 kA, Obsolete","metaDescription":"MGP2504X is an obsolete PowerPacT 4 MCCB, 250 A at 40 °C, 36 kA Icu at 415 V AC, BS EN 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Voltage":"415 V AC 50/60 Hz","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Insulation Voltage Ui":"800 V","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Circuit breaker","Thermal Protection Adjustment Range":"175–250 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47bd5b66affb0412d6e78eb99d2dd1f1.pdf","sourceUrl":"https://www.se.com/uk/en/product/MGP2504X/powerpact-4-molded-case-circuit-breaker-3p-+-n-250a-415-v-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGP2504X/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP2504X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP2504X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}