{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP26800E10","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP26800E10","canonicalUrl":"https://aoctrl.com/schneider/MGP26800E10","factsUrl":"https://aoctrl.com/api/mcp/products/MGP26800E10","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPact M, MGP26800E10, 2-pole circuit breaker, 300-800 A, electronic ET 1.0 trip unit, 65 kA at 240 V AC, UL/CSA/IEC.","salesMarkdown":"The MGP26800E10 is a 2-pole PowerPact M circuit breaker from Schneider Electric, rated 300–800 A continuous with an electronic ET 1.0 trip unit. That 300–800 A range covers large feeders and heavy branch circuits in distribution panels — the trip unit is field-adjustable, so one frame size handles multiple load currents without swapping hardware. The 65 kA AIR at 240 V AC (UL 489) means it can interrupt a fault up to that level without upstream cascading; at 480 V AC the interrupting rating drops to 35 kA, and at 600 V AC to 18 kA — important when you're tying this into a 480 V switchboard and need to verify the available fault current is within the breaker's rating. The magnetic tripping window is 1600–8000 A, which is the instantaneous pickup range for short-circuit protection. For a 400 A setting, that's 4–20× In — typical for a distribution breaker feeding motor loads or transformer feeders where you want to ride through inrush without nuisance trips. If you need Modbus metering or energy monitoring, you'd step up to the ET 2.0 or ET 4.0 trip units in the same PowerPact M frame. ## Deployment context This breaker mounts with unit-mount lugs (AL800M23K terminal kit included) and accepts 3 × AWG 3/0 to 3 × 500 kcmil copper or aluminum — substantial cable sizes for a 300–800 A feed. The lug torque spec is 50 N·m (442.5 lbf·in) for the 95–240 mm² range. It's rated IP40, so it's for indoor panel installation, not washdown environments. The HACR rating means it's listed for heating, air-conditioning, and refrigeration equipment — a common requirement in commercial HVAC panels. The operating altitude limit is 2000 m without derating; up to 4000 m with derating applied. The MGP26800E10 carries UL 489, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 approvals — covering the US, Canada, Mexico, and international IEC markets. CE marking is also listed. This breadth of approvals simplifies panel certification for machines or switchgear shipped across multiple regions.","metaTitle":"MGP26800E10 PowerPact M Circuit Breaker, 300-800 A, 2P, ET 1","metaDescription":"MGP26800E10 PowerPact M circuit breaker, 2-pole, 300-800 A, electronic ET 1.0 trip unit, 65 kA at 240 V AC. UL/CSA/IEC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Color":"Black","Depth":"8.05 in (204.47 mm)","Range":"PowerPact","Width":"8.27 in (210.06 mm)","title":"MGP26800E10","Height":"12.86 in (326.64 mm)","Category":"US10DE201205","AWG gauge":"3 x AWG 3/0...3 x 500 kcmil aluminium/copper","Standards":"UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2","description":"Circuit breaker, PowerPacT M, 300A to 800A, 2 pole, 600VAC, 18kA, lugs, adjustable trip, 80%","Control Type":"Operating handle","Product name":"PowerPact M","Mounting mode":"Unit mount lug)","Quality labels":"CE","Trip unit name":"ET 1.0","Number of Poles":"2P","Number of slots":"2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 voltage release MN or MX plug-in)","lifecycle_stage":"current","Local signalling":"1 trip indicator green)","Mounting Support":"Lug","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Breaking capacity":"AIR 65 kA 240 V AC 50/60 Hz UL 489 AIR 35 kA 480 V AC 50/60 Hz UL 489 AIR 18 kA 600 V AC 50/60 Hz UL 489 Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2","Network Frequency":"50/60 Hz","Tightening torque":"442.5 lbf.in (50 N.m) 0.1...0.4 in² (95...240 mm²) (3 x AWG 3/0...3 x 500 kcmil)","Device Application":"Distribution","Line Rated Current":"300...800 A","Operating altitude":"< 6561.68 ft (2000 m) without derating 13123.36 ft (4000 m) with derating","Terminal identifier":"AL800M23K","Trip unit technology":"Electronic, basic, ET 1.0,","Utilisation category":"Category A","Electrical connection":"Terminal nut, line Lugs, load","Nbr. of units in pkg.":"1","Breaking capacity code":"G","Communication interface":"Modbus","IP degree of protection":"IP40","Continuous current rating":"80 %","Magnetic tripping current":"1600...8000 A","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes IEC 60947-2","Circuit breaker application":"HACR rated","Power wire stripping length":"1.0 in (25 mm)","[Ui] rated insulation voltage":"750 V IEC 60947-2","Accessory / separate part type":"Communication module","[Ue] rated operational voltage":"600 V AC 50/60 Hz UL 489","Long time pick-up adjustment range":"300...800 A","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"25 kA 240 V AC 50/60 Hz IEC 60947-2 20 kA 380/415 V AC 50/60 Hz IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/85db24dfd017802b4d0d186a5f3efa71.pdf","sourceUrl":"https://www.se.com/us/en/product/MGP26800E10/circuit-breaker-powerpact-m-300a-to-800a-2-pole-600vac-18ka-lugs-adjustable-trip-80/"},"ai":{"faq":[{"question":"Who supplies MGP26800E10 and how is it quoted for volume purchases?","answer":"The MGP26800E10 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is listed here."},{"question":"What are the key ratings of MGP26800E10?","answer":"The MGP26800E10 is a 2-pole PowerPact M circuit breaker rated 300–800 A continuous with an electronic ET 1.0 trip unit. Its interrupting rating is 65 kA at 240 V AC (UL 489), 35 kA at 480 V AC, and 18 kA at 600 V AC. Magnetic trip range is 1600–8000 A."},{"question":"What compliance documentation does this brand provide for MGP26800E10?","answer":"The MGP26800E10 is certified to UL 489, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2, plus CE marking. These cover US, Canadian, Mexican, and international IEC markets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP26800E10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP26800E10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}