{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP36600SA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP36600SA","canonicalUrl":"https://aoctrl.com/schneider/MGP36600SA","factsUrl":"https://aoctrl.com/api/mcp/products/MGP36600SA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPact M unit mount breaker, MGP36600SA, 600A, 3-pole, 18kA at 600VAC, electronic trip, shunt trip 120V, lugs off end.","salesMarkdown":"## MGP36600SA — PowerPact M Unit Mount Breaker, 600A The MGP36600SA is a Schneider Electric PowerPact M unit mount breaker rated 600A continuous, 3-pole, with an interrupting capacity of 18 kA at 600 VAC. It comes with an electronic trip unit, a 120V shunt trip for remote opening, and lugs off the end for line/load connections. This is a full-frame, high-current breaker sized for main or large feeder protection in switchboards, panelboards, or standalone enclosures. 600A continuous rating means this breaker carries a full 600A load without tripping under normal conditions — sized for a main disconnect or a large feeder feeding a downstream subpanel or heavy motor load center. The electronic trip unit offers adjustable long-time, short-time, and instantaneous pickup — field-configurable for coordination with downstream breakers, unlike a fixed thermal-magnetic trip. ## Deployment Context This is a unit mount breaker — it bolts into a switchboard or panelboard mounting pan, not a DIN rail. The lugs off the end accept cable or bus connections from the line side (top) and load side (bottom). The 120V shunt trip allows remote tripping from a fire alarm system, emergency stop circuit, or PLC output. Panel builders should verify lug wire range and torque specs from the PowerPact M installation guide before terminating.","metaTitle":"MGP36600SA PowerPact M Unit Mount Breaker, 600A, 18kA","metaDescription":"MGP36600SA PowerPact M unit mount breaker, 600A, 3-pole, 18kA at 600VAC, electronic trip, shunt trip 120V. Obsolete — sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b3816d84cab2f69f4cfba1a4ee1fda97.pdf","sourceUrl":"https://www.se.com/us/en/product/MGP36600SA/circuit-breaker-powerpact-m-unit-mount-electronic-trip-600a-3-pole-18-ka-600-vac-shunt-trip-120v-lugs-off-end/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGP36600SA/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP36600SA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP36600SA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}