{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MGP6304XFO","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"MGP6304XFO","canonicalUrl":"https://aoctrl.com/schneider/MGP6304XFO","factsUrl":"https://aoctrl.com/api/mcp/products/MGP6304XFO","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerPacT 4 basic frame, MGP6304XFO, 630 A, 4P, 50 kA Icu at 415 V AC, without trip unit, obsolete.","salesMarkdown":"The MGP6304XFO is a PowerPacT 4 basic frame rated 630 A continuous, 4 poles, with a 50 kA Icu and Ics at 415 V AC 50/60 Hz — that breaking capacity means it can safely clear a fault up to 50 kA without the arc flashing over, which is the standard interrupt rating for heavy distribution panelboards in commercial and light industrial mains. It's a Category A breaker (no intentional short-time delay), so it's sized for instantaneous trip coordination downstream of a larger main. This is a basic frame — no trip unit included, no earth-leakage module. The buyer sources the trip unit separately (typically a Micrologic or standard thermal-magnetic plug-in) to set the protection curve. The contact position indicator and isolation suitability per BS EN 60947-2 mean it doubles as a visible-break disconnect for lockout/tagout when the trip unit is fitted. Panel-mounted via backplate support, 6-module wide at 35 mm per module (185 mm total width), 255 mm tall, 110 mm deep. Mounts horizontally or vertically. IP40 front face keeps out tools and fingers; IK07 impact rating means it survives a 2 J hammer blow without cracking the case. Pollution degree 3 per EN/IEC 60664-1 — rated for conductive pollution in industrial enclosures, so no additional conformal coating needed in a typical panel environment. Altitude derating applies above 2000 m. Mechanical endurance rated at 15,000 cycles. Electrical endurance at 440 V In/2: 8000 cycles, dropping to 4000 cycles at full rated current In. That's typical for a molded-case frame of this class — the contacts are sized for the 630 A continuous rating, not for frequent switching. This is a distribution breaker, not a motor-switching device. The toggle control and contact position indicator give visual confirmation of state.","metaTitle":"MGP6304XFO PowerPacT 4 Breaker Frame, 630A 4P 50kA, Obsolete","metaDescription":"MGP6304XFO PowerPacT 4 basic frame, 630 A, 4 poles, 50 kA Icu at 415 V AC. Obsolete per manufacturer. Sourced to order against RFQ through independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"110 mm","Width":"185 mm","Colour":"Grey","Height":"255 mm","Standards":"BS EN 60947-2","Control type":"Toggle","Trip unit name":"NA","lifecycle_stage":"current","Mounting support":"Backplate","Pollution degree":"3 conforming to EN/IEC 60664-1","Range of product":"PowerPacT 4","Mounting position":"Horizontal and vertical","Number of modules":"6 module(s)35 mm","Performance level":"N","Poles description":"4P","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"630 A","Product destination":"400/630 A panelboard","Utilisation category":"Category A","Electrical durability":"8000 cycles at 440 V In/2 4000 cycles at 440 V In","Mechanical durability":"15000 cycles","IK degree of protection":"IK07 conforming to EN/IEC 62262","IP degree of protection":"IP40 conforming to EN/IEC 60529","Earth-leakage protection":"Without","Product or component type":"Basic frame","Suitability for isolation":"Yes conforming to BS EN 60947-2","Contact position indicator":"Yes","Circuit breaker mounting mode":"Panel-mounted","[Ui] rated insulation voltage":"800 V","[Ue] rated operational voltage":"415 V AC 50/60 Hz","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ics] rated service short-circuit breaking capacity":"50 kA at 415 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"50 kA Icu at 415 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5d32492bd748891b8ea8c6da814c68f7.pdf","sourceUrl":"https://www.se.com/uk/en/product/MGP6304XFO/breaker-frame-powerpact-4-630a-4p-50ka-without-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/MGP6304XFO/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy MGP6304XFO and how is it quoted?","answer":"We source the MGP6304XFO through independent distribution channels against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published because the part is obsolete and each lot is sourced individually."},{"question":"What compliance documentation does Schneider provide for MGP6304XFO?","answer":"The frame is certified to BS EN 60947-2, with isolation suitability per that standard. IP40 per EN/IEC 60529, IK07 per EN/IEC 62262, pollution degree 3 per EN/IEC 60664-1, and Class II electrical shock protection. The evidence does not list RoHS, REACH, or UL documentation — those would need to be sourced from the original manufacturer's archive for this obsolete part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/MGP6304XFO","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/MGP6304XFO when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}