{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MS132-6.3","brand":"ABB","brandSlug":"abb","productSlug":"MS132-6.3","canonicalUrl":"https://aoctrl.com/abb/MS132-6.3","factsUrl":"https://aoctrl.com/api/mcp/products/MS132-6.3","rawCanonicalId":null},"summary":{"shortDescription":"ABB MS132-6.3 Manual Motor Protector, 3-phase, 4.0–6.3 A FLA range, 600 VAC rated, Trip Class 10, 45 mm width, rotary handle.","salesMarkdown":"## Motor protection window and trip class The MS132-6.3 covers a 4.0 to 6.3 A full-load-amp range, so it protects motors whose nameplate FLA falls inside that band — not below 4 A, not above 6.3 A. Phase-failure detection is built in: if one phase drops out, the protector trips on the unbalance — no separate phase-loss relay needed. Short-circuit protection is integral, so the MS132 serves as both the overload and the branch-circuit short-circuit protective device in a motor starter combination. ## DIN-rail footprint and manual operation At 45 mm wide, the MS132-6.3 fits two units per standard 90 mm DIN-rail section — useful when packing multiple motor starters into a compact panel. The rotary handle provides manual on/off control and resets the trip after a fault; the handle position gives a visual trip indication without opening the enclosure door. The lifecycle stage is marked as current — ABB still produces the MS132-6.3.","metaTitle":"ABB MS132-6.3 Manual Motor Protector, 6.3 A, Trip Class 10","metaDescription":"ABB MS132-6.3 manual motor protector, 4.0–6.3 A FLA, 3-phase, 600 VAC, Trip Class 10. Phase failure detection, 45 mm width. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Amps":"6.300","Type":"Manual Motor Protector","Phase":"3","title":"MS132-6.3","Amps Range":"4 - 6.300","description":"Manual Motor Protector, 4.00 - 6.30 FLA, MS132, Rotary, 600VAC Rated|4.00 - 6.30 FLA (Full Load Amps). MMP, 600V Rated, Trip Class: 10. Type MS132. Includes: Short Circuit Protection and Phase Failure Detection, Small 45 mm Width.","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":47,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/708f50a38ad39beb49b3b43031848442.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is MS132-6.3's listed amps (6.300) on this Motor Starters line?","answer":"The MS132-6.3 is rated for a full-load-amp range of 4.0 to 6.3 A, 3-phase, 600 VAC. The 6.3 A figure is the maximum FLA the protector can be set to."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/MS132-6.3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/MS132-6.3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}