{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"MY2K-US-DC48","brand":"Omron","brandSlug":"omron","productSlug":"MY2K-US-DC48","canonicalUrl":"https://aoctrl.com/omron/MY2K-US-DC48","factsUrl":"https://aoctrl.com/api/mcp/products/MY2K-US-DC48","rawCanonicalId":null},"summary":{"shortDescription":"Omron MY2K-US-DC48 magnetic-latching relay, DPDT (2-pole), plug-in terminal, 48 VDC coil, 3 A max switching, RoHS compliant.","salesMarkdown":"## What a magnetic-latching DPDT plug-in relay actually does The Omron MY2K-US-DC48 is a magnetic-latching relay in the MYK family, defined as a DPDT (2-pole) plug-in device whose contacts hold their last position after the coil is de-energized — ideal for memory- and data-transmission circuits where the output state must survive a power interruption. The set and reset coils run at 48 VDC with a set power of approximately 1.3 W and a reset power of approximately 0.6 W. Two separate coil inputs on the same relay let a logic pulse flip the contacts in either direction without continuous coil hold current, which is the defining advantage of the latching form factor over a standard non-latching DPDT relay. ## Contact ratings and what they mean for the load Maximum switching current is 3 A with a maximum switching voltage of 250 VAC or 125 VDC. The headline 3 A figure is the resistive ceiling; on inductive loads the ratings drop to 0.8 A at 220 VAC and 1.5 A at 24 VDC, while on resistive loads they hold at 3 A at both 220 VAC and 24 VDC. Switching power tracks the same split: 176 VA / 36 W on inductive loads versus 660 VA / 72 W on resistive loads. For a buyer matching this relay to a real load, the duty category — not the headline 3 A — is the figure that governs fit: a relay driving a solenoid or small contactor coil must be sized against the 0.8 A inductive rating, not the 3 A resistive figure. ## Low-level switching and panel-side integration The minimum load of 1 mA at 1 VDC means the contacts are rated for dry-circuit and low-level signal switching, so the relay can sit at the boundary between logic-level telemetry and a higher-current output without a separate interposing relay. Operating temperature runs from -55 °C to 60 °C, covering both unheated outdoor cabinets and standard panel interiors. The plug-in terminal style fits the standard MY-series octal/ blade socket pattern used across the Omron MY family, so panel wiring is a matter of matching the correct socket and pinning the two coil inputs plus the DPDT commons to the wiring layout. RoHS compliance is confirmed on the device record. ## Sourcing posture for MY2K-US-DC48 The lifecycle stage is recorded as mature. No stock or lead-time figures are published on this page.","metaTitle":"Omron MY2K-US-DC48 Latching Relay, DPDT, 48 VDC","metaDescription":"Omron MY2K-US-DC48 magnetic-latching plug-in relay, DPDT, 48 VDC coil, 3 A contacts, RoHS compliant. Sourced to order; availability confirmed at RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["General Purpose Relays"],"specifications":{"title":"MY2K-US-DC48","Terminal":"Plug-in","description":"MYK|Magnetic latching relay ideal for memory- and data-transmission circuits","Coil voltage":"48 VDC","Minimum Load":"1 mA@1 VDC","RoHS compliant":"Yes","lifecycle_stage":"mature","Special function":"Latching Relay","Power consumption":"Set coil: Approx. 1.3 W |Reset coil: Approx. 0.6 W","Contact arrangement":"DPDT","Operating temperature":"-55 to 60°C","Max. switching current":"3 A","Max. switching voltage":"250VAC, 125VDC","Rated load (inductive)":"0.8A@220VAC, 1.5A@24VDC","Rated load (resistive)":"3A@220VAC, 3A@24VDC","Max. switching power(inductive)":"176 VA, 36 W","Max. switching power(resistive)":"660 VA, 72 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.65","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0c9e9fd513fe03c5a14540d84a8decb3.pdf","sourceUrl":"https://automation.omron.com/en/us/products/family/myk"},"ai":{"faq":[{"question":"What compliance documentation does Omron provide for the MY2K-US-DC48?","answer":"The device record declares RoHS compliance. Beyond that explicit declaration, the part carries the standard approvals traceable to the Omron MYK relay family; no separate REACH, UL, or IEC declarations are on file in this ledger, so any additional conformity paperwork should be requested with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/MY2K-US-DC48","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/MY2K-US-DC48 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}