{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"NHJF36090TW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"NHJF36090TW","canonicalUrl":"https://aoctrl.com/schneider/NHJF36090TW","factsUrl":"https://aoctrl.com/api/mcp/products/NHJF36090TW","rawCanonicalId":null},"summary":{"shortDescription":"PowerPacT multistandard - H-Frame - 90 A - 100 KA - Therm-Mag trip unit","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"3.4 in (86 mm)","Range":"PowerPact","Width":"4.09 in (104 mm)","Height":"6.4 in (163 mm)","Standards":"NEMA AB1 IEC 60947-2 W-C-375B/GEN UL 489 NMX J-266 CSA C22.2 No 5","Control type":"Toggle","Display type":"3 LEDs","Product name":"H-Frame","Mounting mode":"Unit mount","Trip unit name":"TM","lifecycle_stage":"unknown","Connection pitch":"1.8 in (45 mm)","Local signalling":"ON/OFF indication","Mounting support":"Backplate Flush DIN rail","Pollution degree":"3 IEC 60947-1 3 IEC 60664-1","Range of product":"PowerPact multistandard","Trip unit rating":"90 A","Breaking capacity":"Icu 100 kA 220/240 V - AC IEC 947-2 Icu 65 kA 380/415 V - AC IEC 947-2 Icu 65 kA 440/480 V - AC IEC 947-2 Icu 25 kA 500/525 V - AC IEC 947-2 100 kA 240 V - AC UL 489 65 kA 480 V - AC UL 489 25 kA 600 V - AC UL 489","Device short name":"H-Frame","Poles description":"3P","Tightening torque":"44.3 lbf.in (5 N.m) 0.004...0.1 in² (2.5...95 mm²) AWG 14...AWG 3/0)","Device application":"Distribution","[In] rated current":"90 A 104 °F (40 °C)","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical connection":"Terminal nut, line side Terminal nut, load side","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Breaking capacity code":"HJ","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Provision for padlocking":"Non padlockable","Product or component type":"Circuit breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","[Ui] rated insulation voltage":"750 V AC 50/60 Hz IEC 60947-2","Trip unit protection functions":"Basic protection","[Ue] rated operational voltage":"525 V AC 50/60 Hz IEC 60947-2 690 V AC 50/60 Hz IEC 947-2 600 V AC 50/60 Hz UL 489","Long time pick-up adjustment range":"1 In","Ambient air temperature for storage":"-58...185 °F (-50...85 °C)","Long time pick-up adjustment type Ir":"Fixed","Ambient air temperature for operation":"104 °F (40 °C)","[Ics] rated service breaking capacity":"Ics 100 kA 220/240 V - AC IEC 947-2 Ics 65 kA 380/415 V - AC IEC 947-2 Ics 65 kA 440/480 V - AC IEC 947-2 Ics 25 kA 500/525 V - AC IEC 947-2","Short-time pick-up adjustment type Isd":"Fixed","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Isd] short-time pick-up adjustment range":"1450 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1816fa6a344feb69e17ed5ecebe1d283.pdf","sourceUrl":"https://www.se.com/ca/en/product/NHJF36090TW/powerpact-multistandard-hframe-90-a-100-ka-thermmag-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/NHJF36090TW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/NHJF36090TW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/NHJF36090TW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}