{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"NTSAMM0600K","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"NTSAMM0600K","canonicalUrl":"https://aoctrl.com/schneider/NTSAMM0600K","factsUrl":"https://aoctrl.com/api/mcp/products/NTSAMM0600K","rawCanonicalId":null},"summary":{"shortDescription":"Analog Input/Output Module + Base, 4 In, 2 Out, Group Isolated, Current, Voltage, 2 Wires, Modicon Edge I/O NTS","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.1 in (80 mm)","Width":"0.6 in (15 mm)","Height":"3.9 in (100 mm)","Marking":"CE UKCA CULus RCM","Category":"US1PC3318214","LSB value":"0.31 mV, +/- 10 V 0.31 mV, 0...10 V 0.16 mV, +/- 5 V 0.16 mV, 0...5 V 0.13 mV, 1...5 V 0.61 µA, +/- 20 mA 0.61 µA, 0...2 mA 0.49 µA, 4...20 mA","Standards":"EN/IEC 61131-2 EN 61010-2-201 UL 61010-2-201 IACS E10 EN/IEC 61000-6-5 EN/IEC 61850-3 EN/IEC 60079-0 EN 50155 EN 50121-4 EN 50121-5","Directives":"2014/30/EU - electromagnetic compatibility 2014/34/EU - ATEX directive 2014/35/EU","Non-linearity":"<= 0.02 % FS analog output","Type of Cable":"Shielded cable","HART tolerance":"Yes","Housing Colour":"Grey","Operating Mode":"Isochronous/Asynchronous","Product Weight":"0.161 lb(US) (0.073 kg)","Input impedance":"> 10 MOhm in voltage mode 100 Ohm","Kit composition":"NTSAMM0600 module NTSXBA0100H base","lifecycle_stage":"unknown","Input diagnostic":"Underflow error per channel Overflow error per channel Broken wire error per channel Hardware error per channel","Local signalling":"1 LED green module operating (RUN) 1 LED per channel green channel diagnostic 1 LED red module error (ERR)","Mounting support":"Top hat type TH35-7.5 rail IEC 60715 Top hat type TH35-15 rail IEC 60715","Pollution degree":"2","Range of Product":"Modicon Edge I/O NTS","Shock resistance":"15 g 11 ms with and without accessory)","Input wiring mode":"1 or 2 wires","Measurement error":"<= 0.5 % FS - 20...60 °C output","Power supply type":"Bus power from power supply bus (24 Vdc) Field power from power supply field (24 Vdc)","Relative humidity":"5...95 % without condensation","Sampling duration":"1.69 ms per module","Temperature drift":"± 0.0057 % FS/ °C input ± 0.0006 % FS/ °C output","Device Application":"Industrial Application","Operating altitude":"0...6561.68 ft (0...2000 m) 2000...5000 m with derating","Output wiring mode":"2 wires","Analogue input type":"Current +/- 20 mA Current 0...20 mA Current 4...20 mA Voltage +/- 10 V Voltage 0...10 V Voltage +/- 5 V Voltage 0...5 V Voltage 1...5 V","Mandatory accessory":"NTSXTB18_0_H terminal block","Analogue output type":"Current 0...20 mA Current 4...20 mA Voltage +/- 10 V Voltage 0...10 V Voltage +/- 5 V Voltage 0...5 V Voltage 1...5 V","Load impedance ohmic":"600 Ohm current 1 kOhm voltage","Vibration resistance":"1 g without accessory 2 g with accessory","Analogue input number":"4","Common mode rejection":"90 dB","Hot swapping fallback":"Yes","Input protection type":"Over current / miswiring protection per channel for current input Over voltage / miswiring protection per channel for voltage input","Nbr. of units in pkg.":"1","Analogue output number":"2","Output protection type":"30V over voltage for current output","Power dissipation in W":"2.3 W maximum at 24 V DC","IP Degree of Protection":"IP20","Isolation between group":"530 V AC","Response time on output":"1.2 ms at 600 Ohm per module","Analogue input resolution":"15 bits + sign","Product or Component Type":"Analog input module kit","Typical current consumption":"37.4 mA 24 V DC on the Bus current 28.3 mA 24 V DC on the internal field current minimum 80.4 mA 24 V DC on the internal field current maximum","Environmental characteristic":"Gas resistant C3 and G2","Permitted overload on inputs":"30 V maximum voltage 30 V at 50 mA maximum current","Rated operational voltage limits":"20.4...28.8 V DC","Isolation between channels and bus":"1500 V AC","Ambient air temperature for storage":"-40...185 °F (-40...85 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","Isolation between field power and bus":"1500 V AC","Maximum cable distance between devices":"Shielded cable Shielded cable Shielded cable Shielded cable <3280.8 ft (1000 m) current output","Isolation between channels and field pwr":"1000 Vac for input 1000 Vac for output"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/NTSAMM0600K/analog-input-output-module-+-base-4-in-2-out-group-isolated-current-voltage-2-wires-modicon-edge-i-o-nts/","alternativesUrl":"https://aoctrl.com/api/mcp/products/NTSAMM0600K/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/NTSAMM0600K","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/NTSAMM0600K when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}