{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"OD2-P120W60C2","brand":"SICK","brandSlug":"sick","productSlug":"OD2-P120W60C2","canonicalUrl":"https://aoctrl.com/sick/OD2-P120W60C2","factsUrl":"https://aoctrl.com/api/mcp/products/OD2-P120W60C2","rawCanonicalId":null},"summary":{"shortDescription":"SICK OD Value series 2D Laser Displacement Sensor, OD2-P120W60C2, 12 ~ 24VDC, PNP output, 60.0mm ~ 180.0mm installation distance, IP67, chassis mount with cable leads.","salesMarkdown":"The OD2-P120W60C2 is a 2D laser displacement sensor from the SICK OD Value series, delivering a measurement range of 120mm ±60mm from a reference distance of 60mm to 180mm. That 120mm span means it can profile a part's height or gap variation across a 120mm-wide swath in a single pass — useful for weld-seam tracking, adhesive bead inspection, or component presence verification on a moving line. The PNP output (sourcing) is the common choice for PLC inputs that expect a positive signal; if your card is sinking (NPN), you will need the NPN variant or an interposing relay. The 12 ~ 24VDC supply range is standard for industrial sensors, but the 40°C upper operating temperature limit means you derate if the sensor sits near a drying oven or hot-melt station — the -10°C floor is fine for unheated warehouses. ## Deployment context IP67 rating means the housing and optics survive washdown — suitable for food-and-bev lines, machining coolant splash, or outdoor conveyor gantries provided the cable entry is properly glanded. Chassis mount with cable leads; plan for a strain-relief bracket if the cable sees flex in a robot cell. The 60mm minimum standoff keeps the sensor clear of collision with the target, while the 180mm maximum gives flexibility for varying part heights on the same fixture.","metaTitle":"OD2-P120W60C2 2D Laser Displacement Sensor, 120mm Range, PNP","metaDescription":"OD2-P120W60C2 2D laser displacement sensor, 12~24VDC, IP67, 60-180mm install distance, PNP output. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Proximity Sensors"],"specifications":{"Type":"2D Laser Displacement Sensor","Series":"OD Value","Package":"Bulk","Mounting Type":"Chassis Mount","lifecycle_stage":"current","Voltage - Supply":"12 ~ 24VDC","Termination Style":"Cable Leads","Ingress Protection":"IP67 - Dust Tight, Waterproof","Installation Distance":"60.0mm ~ 180.0mm","Operating Temperature":"-10°C~40°C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/OD2-P120W60C2/alternatives.json"},"ai":{"faq":[{"question":"When sourcing OD2-P120W60C2, what's the closest functional second-source — OD2-P120W60U2?","answer":"The OD2-P120W60U2 is electrically and mechanically identical — same 12~24VDC supply, same 60-180mm installation distance, same IP67 chassis-mount form factor — but outputs a voltage (analog) signal instead of PNP discrete. If your PLC input card expects a discrete PNP signal, the U2 will not drop in without rewiring the output side. The OD2-P120W60A2 and OD2-P120W60I2 are the other output-variant siblings (analog current and IO-Link, respectively); all share the same footprint and mounting, so the mechanical fit is identical across the four."},{"question":"What is OD2-P120W60C2's listed type (2D Laser Displacement Sensor) on this component line?","answer":"The type is 2D Laser Displacement Sensor. It projects a laser line to measure height profiles across a 120mm width, not a single-point distance."},{"question":"What is OD2-P120W60C2's listed series (OD Value) on this component line?","answer":"The series is OD Value, SICK's compact 2D displacement sensor family designed for inline profile measurement in factory automation."},{"question":"Will OD2-P120W60C2 drop into a panel that was specified around OD2-P120W60U2 without rewiring?","answer":"Mechanically yes — same chassis mount, same cable leads, same 60-180mm installation distance, same IP67 housing. Electrically, the C2 outputs PNP discrete; the U2 outputs a voltage analog signal. If the existing PLC input card is wired for analog voltage, the C2 will not work without rewiring the output to a discrete input. If the card accepts both, confirm the input type and voltage range before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/sick/OD2-P120W60C2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/sick/OD2-P120W60C2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}