{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"PLM34120CU44A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"PLM34120CU44A","canonicalUrl":"https://aoctrl.com/schneider/PLM34120CU44A","factsUrl":"https://aoctrl.com/api/mcp/products/PLM34120CU44A","rawCanonicalId":null},"summary":{"shortDescription":"MOLDED CASE CIRCUIT BREAKER 480V 1200A|MOLDED CASE CIRCUIT BREAKER 480V 1200A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"8.05 in (204.47 mm)","Range":"PowerPact","Width":"8.27 in (210.06 mm)","Height":"16.16 in (410.46 mm)","Category":"US10DE201215","AWG gauge":"4 x AWG 3/0...500 kcmil aluminium/copper","Standards":"UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2","Control Type":"Toggle","Product name":"PowerPact P","Mounting mode":"Unit mount lug)","Quality labels":"CE","Trip unit name":"MicroLogic 6.0 A","Number of Poles":"3P","Number of slots":"2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in)","lifecycle_stage":"unknown","Local signalling":"Overload 1 trip indicator green) 1 trip indicator green) Trip causes 1 trip indicator green)","Mounting Support":"Lug","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Breaking capacity":"AIR 125 kA 240 V AC 50/60 Hz UL 489 AIR 100 kA 480 V AC 50/60 Hz UL 489 AIR 25 kA 600 V AC 50/60 Hz UL 489 Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2","Network Frequency":"50/60 Hz","Tightening torque":"442.5 lbf.in (50 N.m) 0.1...0.4 in² (95...240 mm²) (4 x AWG 3/0...500 kcmil) 8.9...11.5 lbf.in (1.0...1.3 N.m)","Device Application":"Distribution","Line Rated Current":"1200 A","Operating altitude":"< 6561.68 ft (2000 m) without derating 13123.36 ft (4000 m) with derating","Terminal identifier":"AL1200P25K","Trip unit technology":"Electronic, ammeter, MicroLogic 6.0 A, LSIG","Electrical connection":"Lugs, line Terminal nut, load","Nbr. of units in pkg.":"1","Breaking capacity code":"L","IP degree of protection":"Front cover IP40","Continuous current rating":"100 %","Product or Component Type":"Circuit breaker","Circuit breaker application":"HACR rated","Power wire stripping length":"1.2 in (30 mm)","[Ui] rated insulation voltage":"750 V IEC 60947-2","[Ue] rated operational voltage":"480 V AC 50/60 Hz UL 489","Long time pick-up adjustment range":"0.4...1 x Ir","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"65 kA 240 V AC 50/60 Hz IEC 60947-2 45 kA 380/415 V AC 50/60 Hz IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,608.70","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b2d225b15d509cc43b7096848b6c0d8d.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/PLM34120CU44A/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/PLM34120CU44A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/PLM34120CU44A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}