{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"PP44003X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"PP44003X","canonicalUrl":"https://aoctrl.com/schneider/PP44003X","factsUrl":"https://aoctrl.com/api/mcp/products/PP44003X","rawCanonicalId":null},"summary":{"shortDescription":"PP44003X by SCHNEIDER ELECTRIC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"140 mm","Colour":"Grey","Height":"255 mm","Standards":"BS EN 60947-2","Control type":"Toggle","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.3","Protection type":"L : for overload protection (thermal) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"unknown","Local signalling":"Flashing LED (green) for ready to operate LED 90 % Ir (orange) for pre-alarm indicator LED 105 % Ir (red) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to EN/IEC 60664-1","Range of product":"PowerPacT 4","Trip unit rating":"400 A at 40 °C","Mounting position":"Horizontal and vertical","Number of modules":"4 module(s)35 mm","Performance level":"F","Poles description":"3P","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000...5000 m with derating","[In] rated current":"400 A at 40 °C","Product destination":"400/630 A panelboard","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"12000 cycles at 440 V In/2 6000 cycles at 440 V In","Mechanical durability":"15000 cycles","IK degree of protection":"IK07 conforming to EN/IEC 62262","IP degree of protection":"IP40 conforming to EN/IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to BS EN 60947-2","Contact position indicator":"Yes","Power dissipation per pole":"19.2 W","Circuit breaker mounting mode":"Panel-mounted","[Ui] rated insulation voltage":"800 V","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"415 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"160...400 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"36 kA at 415 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"50 kA Icu at 415 V AC 50/60 Hz","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"4800 A","Long-time pick-up adjustment type Ir (thermal protection)":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,303.02","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a172677234f2b51948b6f13a900d9a53.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/PP44003X/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/PP44003X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/PP44003X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}