{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"PXF9ACP2-JBCA1","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"PXF9ACP2-JBCA1","canonicalUrl":"https://aoctrl.com/fuji-electric/PXF9ACP2-JBCA1","factsUrl":"https://aoctrl.com/api/mcp/products/PXF9ACP2-JBCA1","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric PXF9ACP2-JBCA1, 1/4 DIN (96 x 96 mm) compact temperature and process controller, self-tuning PID, 50 ms sampling speed, current lifecycle stage.","salesMarkdown":"## 50 ms sampling with self-tuning — what it means for your loop The PXF9ACP2-JBCA1 samples the process variable every 50 ms — fast enough to catch thermal transients in injection molding barrels or reflow ovens without aliasing. The self-tuning algorithm maps the process response curve on startup and sets PID terms automatically, so you skip the manual Ziegler-Nichols iteration. For a loop that drifts with load changes (batch reactors, extruders), the adaptive function re-tunes on the fly. ## Panel fit — 1/4 DIN footprint Standard 96 x 96 mm cutout — drops into any existing 1/4 DIN panel opening without adapter plates. The depth clears most enclosure back panels; no special DIN-rail bracket required for the panel mount.","metaTitle":"Fuji Electric PXF9ACP2-JBCA1 1/4 DIN Temperature Controller","metaDescription":"Fuji Electric PXF9ACP2-JBCA1 1/4 DIN temperature and process controller with self-tuning PID and 50 ms sampling. Current lifecycle stage. Sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Process / Temperature Controllers"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$363.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/37989152d546f97d9898d5a9f1bd8830.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/PXF9ACP2-JBCA1/alternatives.json"},"ai":{"faq":[{"question":"What does the 50 ms sampling speed mean for my process?","answer":"The controller reads the input every 50 milliseconds, which captures fast thermal changes in processes like injection molding, packaging seal bars, or small-zone reflow ovens. Combined with the self-tuning PID, it settles the loop without overshoot hunting on most thermal loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/PXF9ACP2-JBCA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/PXF9ACP2-JBCA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}