{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"PXF9APY2-JVCA1","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"PXF9APY2-JVCA1","canonicalUrl":"https://aoctrl.com/fuji-electric/PXF9APY2-JVCA1","factsUrl":"https://aoctrl.com/api/mcp/products/PXF9APY2-JVCA1","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric PXF9APY2-JVCA1 temperature and process controller, 1/4 DIN (96 x 96 mm), self-tuning PID, 50 ms sampling speed, current lifecycle stage.","salesMarkdown":"## 50 ms sampling in a 1/4 DIN footprint The PXF9APY2-JVCA1: At 50 ms per sample, the PID loop can respond to a step change in under three cycles — fast enough for most plastics and packaging thermal processes without needing a dedicated high-speed module. ## Panel fit and integration constraints The 1/4 DIN (96 x 96 mm) panel cutout is the standard form factor for temperature controllers — drops into the same hole as a Fuji PXR or PXV series without re-cutting the panel.","metaTitle":"Fuji Electric PXF9APY2-JVCA1 Temperature Controller, 1/4 DIN","metaDescription":"Fuji Electric PXF9APY2-JVCA1 1/4 DIN temperature/process controller, 50ms sampling, self-tuning PID. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Process / Temperature Controllers"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$363.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/37989152d546f97d9898d5a9f1bd8830.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/PXF9APY2-JVCA1/alternatives.json"},"ai":{"faq":[{"question":"What does the 50 ms sampling speed mean for a thermal process?","answer":"A 50 ms sampling period means the controller reads the input and updates the output 20 times per second. For a fast-responding load like a small cartridge heater in a thermocouple well, this prevents the overshoot that a 100 ms loop would allow on the first heating cycle."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/PXF9APY2-JVCA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/PXF9APY2-JVCA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}