{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"QD75P1N","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"QD75P1N","canonicalUrl":"https://aoctrl.com/mitsubishi/QD75P1N","factsUrl":"https://aoctrl.com/api/mcp/products/QD75P1N","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric QD75P1N positioning unit, open collector output type, 1-axis control, 200 kpps max output pulse, 32-point intelligent I/O assignment, 27.4 mm wide.","salesMarkdown":"## 1-axis positioning with open collector output The QD75P1N is a single-axis positioning module for Mitsubishi PLC systems, outputting pulse trains via open collector outputs at up to 200 kpps. It occupies 32 I/O points as an intelligent module, drawing 0.29 A from the 5 V backplane. Control methods include PTP (point-to-point), linear/circular/helical trajectory, speed control, and position/speed switching — all selectable per positioning data block. Acceleration/deceleration uses trapezoidal or S-curve profiles with independent accel/decel times per pattern. ## Positioning range and data storage Positioning data is stored in flash ROM with no battery required — parameters, positioning data, and block start data survive power loss without a backup battery. The module supports 600 positioning data points per axis. Command units can be set to mm, inch, degree, or pulse. The absolute positioning range spans ±214748364.8 μm, ±21474.83648 inch, 0 to 359.99999 degree, or ±2147483648 pulses. Incremental positioning covers the same range. ## Wiring and physical fit External wiring connects through a 40-pin connector (mates with A6CON1, A6CON2, or A6CON4, sold separately). Maximum cable distance between the module and servo drive is 2 m. The module measures 27.4 mm wide, 98 mm high, and 90 mm deep. No stock-holding claim — quoted per order.","metaTitle":"Mitsubishi QD75P1N Positioning Unit, 1-Axis Open Collector","metaDescription":"Mitsubishi QD75P1N 1-axis positioning unit, open collector output, 200 kpps max pulse. Mature lifecycle, battery-less flash ROM backup. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Mass":"0.14 Kg","title":"QD75P1N","Backup":"Parameter, positioning data, block start data can be saved in flash ROM (battery less)","Depth (D)":"90 mm","Width (W)":"27.4 mm","description":"Positioning unit (open collector output type) QD75P1N","Control unit":"mm, inch, degree, pulse","Control Method":"PTP (Point To Point) control trajectory control (both linear, circular and helical can be set) Speed ??control speed / position switching control position / speed switching control","Shipping Weight":"1.2 Kg","Speed ??command":"0.01 to 20000000.00 mm / min 0.001 to 2000000.000 inch / min 0.001 to 2000000.000 deg / min 1 to 4000000 pulse / s","lifecycle_stage":"mature","Increment method":"-214748364.8 to 214748364.7 μm . -21474.83648 to 21474.83647 inch . -21474.83648 to 21474.83647 degrees . -2147483648 to 2147483647 pulse","Positioning data":"600 data / axis","Trajectory control":"Increment method / absolute method","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Pulse output method":"Open collector output","1 Axis Speed Control":"1.5 ms","Applicable connector":"A6CON1, A6CON2, A6CON4 (sold separately)","Maximum output pulse":"200 k pulse / s","Number of control axes":"1 axis","Sudden stop deceleration time":"1 to 8388608 ms","External dimensions Height (H)":"98 mm","Number of occupied I / O points":"32 points (I / O assignment: 32 points of intelligence)","External wiring connection method":"40 pin connector","Positioning range Absolute method":". -214748364.8 to 214748364.7 μm . -21474.83648 to 21474.83647 inch . 0 to 359.99999 degree . -2147483648 to 2147483647 pulse","Acceleration and deceleration time":"1 to 8388608 ms Four patterns can be set for both acceleration time and deceleration time","Factors that increase startup time":"In the case of the following conditions, add the time stated below. . When S- curve acceleration / deceleration selection: 0.1 ms . When other axis is in operation: 0.5 ms . For continuous positioning control: 0.3 ms . For continuous trajectory control: 0.3 ms","Position / speed switching control":"Increment method","DC 5 V Internal current consumption":"0.29 A","Speed ??/ position switching control":"Increment method / absolute method","Start time Single axis linear control":"1.5 ms","Acceleration / deceleration processing":"Trapezoidal acceleration / deceleration, S-shaped acceleration / deceleration","Maximum connection distance between servos":"2 m","Positioning Positioning method PTP control":"Increment method / absolute method","Speed ??/ position switching control (ABS mode)":". 0 to 359.99999 degree"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$465.00 – $695.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/66b4b5e9797395d82239d3f45835fdb8.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the maximum pulse output frequency of the QD75P1N?","answer":"The maximum output pulse frequency is 200 kpps (200,000 pulses per second) via the open collector output. This limits the achievable motor speed based on the encoder resolution and servo amplifier input frequency."},{"question":"Does the QD75P1N require a battery to retain positioning data?","answer":"No. The QD75P1N stores parameters, positioning data, and block start data in flash ROM — battery-less backup. No battery is needed for data retention during power-off."},{"question":"What connector does the QD75P1N use, and what is the cable length limit?","answer":"The module uses a 40-pin connector compatible with Mitsubishi A6CON1, A6CON2, or A6CON4 (sold separately). The maximum cable distance between the module and the servo drive is 2 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/QD75P1N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/QD75P1N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}