{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RE22R1QCMU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RE22R1QCMU","canonicalUrl":"https://aoctrl.com/schneider/RE22R1QCMU","factsUrl":"https://aoctrl.com/api/mcp/products/RE22R1QCMU","rawCanonicalId":null},"summary":{"shortDescription":"TIMER 24-240VAC/VDC IN 8A SPDT O","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Width":"0.9 in (22.5 mm)","Category":"US10CP222376","Standards":"UL 508 IEC 61812-1","Directives":"2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive","Status LED":"Green LED backlight steady)dial pointer indication Yellow LED steady)output relay energised Yellow LED fast flashing)timing in progress and output relay de-energised Yellow LED slow flashing)timing in progress and output relay energised","Control Type":"With test button","Control type":"Rotary knob Diagnostic button","Recovery time":"120 ms on de-energisation","Voltage drift":"+/- 0.2 %/V","Voltage range":"0.85...1.1 Us","Power on delay":"100 ms","Repeat accuracy":"+/- 0.5 % IEC 61812-1","Time delay type":"Star-delta - Qc-Star-delta relay (1 CO output)","lifecycle_stage":"current","Housing material":"Polycarbonate","Mounting support":"35 mm DIN rail conforming to IEC 60715","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Timer Relays","Shock resistance":"15 gn not operating 11 ms IEC 60068-2-27 5 gn in operation 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Time delay range":"10...100 s 3...30 s 0.1...1 s 0.3...3 s 0.05...0.5 s 1...10 s 30...300 s","Creepage distance":"4 kV/3 IEC 60664-1","Device short name":"RE22","Mounting position":"Any position","Relative humidity":"95 % 77...131 °F (25...55 °C)","Temperature Drift":"+/- 0.05 %/°C","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1","Function available":"Qc-Star-delta relay (1 CO output)-1 C/O","Dielectric strength":"2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1","Number of functions":"1","Discrete output type":"Relay","Overvoltage category":"III conforming to IEC 60664-1","Vibration resistance":"20 m/s² (f= 10...150 Hz) conforming to IEC 60068-2-6","Electrical durability":"100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1","Insulation resistance":"100 MOhm 500 V DC IEC 60664-1","Mechanical durability":"10000000 cycles","Nbr. of units in pkg.":"1","Release input voltage":"<= 2.4 V","Nominal Output Current":"8 A","Power consumption in W":"0.6 W 24 V DC","Connections - terminals":"Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end","IP degree of protection":"IP40 housing: conforming to IEC 60529 IP50 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529","Immunity to microbreaks":"10 ms","Power consumption in VA":"35 VA 240 V AC","Safety reliability data":"MTTFd = 285.3 years B10d = 270000","Switching capacity in VA":"2000 VA","Maximum switching current":"8 A","Maximum switching voltage":"250 V AC","Minimum switching current":"10 mA 5 V DC","Product or Component Type":"Modular timing relay","[Us] rated supply voltage":"24 V DC 24...240 V AC 50/60 Hz","Contacts type and composition":"1 C/O timed contact, cadmium free","Electromagnetic compatibility":"Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11","Setting accuracy of time delay":"+/- 10 % of full scale 25 °C IEC 61812-1","Rated impulse withstand voltage":"5 kV 1.2...50 µs IEC 60664-1","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Operation":"-4...140 °F (-20...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$31.75 – $89.30","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d59683e921c80b71749e237a71c7cb73.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RE22R1QCMU/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RE22R1QCMU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RE22R1QCMU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}