{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RENF22R2MMW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RENF22R2MMW","canonicalUrl":"https://aoctrl.com/schneider/RENF22R2MMW","factsUrl":"https://aoctrl.com/api/mcp/products/RENF22R2MMW","rawCanonicalId":null},"summary":{"shortDescription":"SQD RENF22R2MMW NFC MULTI TIM|SQD RENF22R2MMW NFC MULTI TIM","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Width":"0.9 in (22.5 mm)","Category":"US10CP222376","Standards":"IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-4 EN 61812-1 IEC 61000-6-3","Directives":"2014/35/EU - low voltage directive 2014/53/EU - radio equipment directive 2014/30/EU - electromagnetic compatibility","status LED":"Un, green LED steady)power ON R1, amber LED steady)relay energised R2, amber LED steady)relay energised Pairing, green LED steady)communication status Un, green LED fast blinking)diagnosis mode R1, amber LED blinking)timing in progress R2, amber LED blinking)timing in progress","Control Type":"Without test button","Recovery time":"120 ms on de-energisation","Voltage drift":"+/- 0.2 %/V","Voltage range":"0.85...1.1 Un","Power On Delay":"100 ms","App for product":"Ecostruxure Industrial Device downloadable from Google Play store or Apple Store)","Repeat accuracy":"+/- 0.2 % 10 s...999 h +/- 0.5 % 100 ms...10 s +/- 0.7 % 50...100 ms","Time delay type":"Power on-delay - A- Power on-delay relay On-delay and off-delay - Ac- On-delay and off-delay relay w/ control signal Pulse delay - Ad- Pulse delayed relay w/ control signal Pulse delay - Ah- Pulse delayed relay (single cycle) w/ control signal On-delay and off-delay - Ak- Asymmetrical on-delay and off -delay relay w/ control signal Power on-delay - At- Power on-delay relay w/ pause/summation (Y1) Interval - B- Single interval relay w/ control signal Interval - Bw- Double interval relay w/ control signal Off-delay - C- Off-delay relay w/ control signal Symmetrical flashing - D- Symmetrical flashing relay (starting pulse-off) Symmetrical flashing - Di- Symmetrical flashing relay (starting pulse-on) Symmetrical flashing - Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1) Symmetrical flashing - Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1) Interval - H- Interval relay Interval - Ht- Interval relay w/ pause/summation (Y1) Asymmetrical flashing - Li- Asymmetrical flashing relay (starting pulse-on) Asymmetrical flashing - Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1) Asymmetrical flashing - Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1) Safe-guard - N- Safe-guard relay Safe-guard - O- Delayed Safe-guard relay Pulse delay - P- Pulse delayed relay w/ fixed pulse length Pulse delay - Pt- Pulse delayed relay w/ fixed pulse length and pause/summation Star-delta - Qt- Star-delta relay (2 CO outputs w/ split common) Star-delta - Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1) Bistable - TI- Bistable relay w/ control signal on Bistable - Tt- Retriggerable bistable relay w/ control signal on Interval - W- Interval relay w/ control signal off Asymmetrical flashing - L- Asymmetrical flashing relay (starting pulse-off)","lifecycle_stage":"unknown","Housing material":"Polycarbonate","Mounting support":"35 mm DIN rail conforming to IEC 60715","Operating system":"Androidversion >= V7.0 IOSversion >= V14.5","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Timer Relays","Shock resistance":"15 gn not operating 11 ms IEC 60068-2-27 5 gn in operation 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Time delay range":"0.05 s...999 h","Creepage distance":"4 kV/3 IEC 60664-1","Device short name":"RENF22","Mounting position":"Any position","Relative humidity":"95 % 77...131 °F (25...55 °C)","Temperature Drift":"+/- 0.05 %/°C","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1 5.3...8.8 lbf.in (0.6...1.0 N.m) IEC 60947-1","Function available":"A- Power on-delay relay-2 C/O Ac- On-delay and off-delay relay w/ control signal-2 C/O Ad- Pulse delayed relay w/ control signal-2 C/O Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O Ak- Asymmetrical on-delay and off -delay relay w/ control signal-2 C/O At- Power on-delay relay w/ pause/summation (Y1)-2 C/O B- Single interval relay w/ control signal-2 C/O Bw- Double interval relay w/ control signal-2 C/O C- Off-delay relay w/ control signal-2 C/O D- Symmetrical flashing relay (starting pulse-off)-2 C/O Di- Symmetrical flashing relay (starting pulse-on)-2 C/O Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O H- Interval relay-2 C/O Ht- Interval relay w/ pause/summation (Y1)-2 C/O Li- Asymmetrical flashing relay (starting pulse-on)-2 C/O Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O N- Safe-guard relay-2 C/O O- Delayed Safe-guard relay-2 C/O P- Pulse delayed relay w/ fixed pulse length-2 C/O Pt- Pulse delayed relay w/ fixed pulse length and pause/summation-2 C/O Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)-2 C/O TI- Bistable relay w/ control signal on-2 C/O Tt- Retriggerable bistable relay w/ control signal on-2 C/O W- Interval relay w/ control signal off-2 C/O L- Asymmetrical flashing relay (starting pulse-off)-2 C/O","Dielectric strength":"2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply with basic insulation basic insulation","Number of functions":"28","Discrete output type":"Relay","Overvoltage category":"III conforming to IEC 60664-1","Vibration resistance":"20 m/s² (f= 10...150 Hz) conforming to IEC 60068-2-6","Electrical durability":"100000 cycles for resistive load, 8 A at 250 V, AC","Insulation resistance":"100 MOhm 500 V DC IEC 60664-1","Mechanical durability":"10000000 cycles","Nbr. of units in pkg.":"1","Release input voltage":"<= 2.4 V","Nominal Output Current":"8 A","Power consumption in W":"1.5 W 240 V DC 0.6 W 24 V DC","Connections - terminals":"Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end","IP degree of protection":"IP40 housing: conforming to IEC 60529 IP40 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529","Immunity to microbreaks":"10 ms","NFC operating frequency":"13.56 MHz","Power consumption in VA":"3 VA 240 V AC","Safety reliability data":"MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C","Switching capacity in VA":"2000 VA","Maximum switching current":"8 A","Maximum switching voltage":"250 V","Minimum switching current":"10 mA 5 V","Product or Component Type":"NFC timer relay","[Us] rated supply voltage":"24...240 V AC/DC","Control signal pulse width":"100 ms with load in parallel 60 ms no-load","Maximum RF power transmitted":"0.0002 mW","Contacts type and composition":"2 C/O timed contact, cadmium free 1 C/O timed and instantaneous contact, cadmium free","Electromagnetic compatibility":"Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 Radiated emission class B conforming to EN 55022 Conducted emission class A conforming to EN 55022 Electromagnetic field immunity test - test level: 3 V/m level 2 (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 Electromagnetic field immunity test - test level: 1 V/m level 1 (2...2.7 GHz) conforming to IEC 61000-4-3","Maximum communication distance":"10 mm","Setting accuracy of time delay":"+/- 1 % 1...999 h 77 °F (25 °C) +/- 2 % 1...3600 s 77 °F (25 °C) +/- 20 ms 100 ms...10 s 77 °F (25 °C) +/- 30 ms 50...100 ms 77 °F (25 °C)","Rated impulse withstand voltage":"5 kV 1.2/50 µs IEC 60664-1","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Operation":"-4...140 °F (-20...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/27cac0f09daa761b0d73c8f6450436d3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RENF22R2MMW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RENF22R2MMW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RENF22R2MMW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}