{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RHN411E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RHN411E","canonicalUrl":"https://aoctrl.com/schneider/RHN411E","factsUrl":"https://aoctrl.com/api/mcp/products/RHN411E","rawCanonicalId":null},"summary":{"shortDescription":"plug-in relay - Zelio RHN - instantaneous - 4 C/O - 48 V AC 50 Hz - 5 A","salesMarkdown":null,"metaTitle":"Schneider RHN411E Plug-in Relay","metaDescription":"Schneider RHN411E Harmony plug-in relay, 4 C/O, 48 V AC, 5 A, instantaneous, for control circuits.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Cos phi":"0.6 (inrush) 0.7 (holding)","Category":"18073-SPARE PARTS DISCOUNT I","Standards":"NF C 45-250 BS 4794 VDE 0435 IEC 60255","Status LED":"Without","Test levels":"Level A group mounting","Control Type":"Manual control","Operating time":"2...15 ms between energisation of coil and closing of NO contact 68 °F (20 °C) 1.2...12 ms between de-energisation of coil and closing of NC contact 68 °F (20 °C) 1...3 ms energisation/de-energisation 0.5...6 ms de-energisation/energisation","lifecycle_stage":"current","Range of Product":"Harmony Relay","Shock resistance":"50 gn 11 ms NF C 20-608","CAD overall depth":"2.1 in (54 mm)","CAD overall width":"1.3 in (33 mm)","Contact operation":"Standard Instantaneous","Device short name":"RHN","Average resistance":"30 mOhm 68 °F (20 °C)","CAD overall height":"1.7 in (43 mm)","Compatibility code":"RHN","Operating position":"Any position","Contact bounce time":"<= 10 ms","Dielectric strength":"2500 V","Maximum voltage drop":"<100 V for 3 A at 24 V","Protective treatment":"TC","Vibration resistance":"6 gn (f= 10...55 Hz) conforming to IEC 60068-2-6 6 gn (f= 10...55 Hz) conforming to NF C 20-616","Mechanical durability":"20000000 cycles","Nbr. of units in pkg.":"1","Maximum Operating Rate":"6 cyc/mn","Product or Component Type":"Plug-in relay","Drop-out voltage threshold":"0.15...0.5 Uc","Minimum switching capacity":"150 mVA 10 mA 150 mVA, 1 V","[Uc] control circuit voltage":"48 V AC 50 Hz","Coil interference suppression":"Without","Contacts type and composition":"4 C/O","[Ui] Rated Insulation Voltage":"250 V","Average coil consumption in VA":"2.5 holding)68 °F (20 °C) 4.5 inrush)68 °F (20 °C)","Control circuit voltage limits":"0.8...1.1 Uc IEC 60255","Terminals description ISO n°1":"(21-22-24)OC (11-12-14)OC (A1-A2)CO (41-42-44)OC (31-32-34)OC","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) IEC 60255","[Ithe] conventional enclosed thermal current":"5 A 104 °F (40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$79.00 – $180.80","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ee0e736e3ecd56d13d1922c2a7e9f982.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RHN411E/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RHN411E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RHN411E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}