{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RKA36120CU64AE1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RKA36120CU64AE1","canonicalUrl":"https://aoctrl.com/schneider/RKA36120CU64AE1","factsUrl":"https://aoctrl.com/api/mcp/products/RKA36120CU64AE1","rawCanonicalId":null},"summary":{"shortDescription":"RKA36120CU64AE1 - 3 POLE by SCHNEIDER ELECTRIC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"14.49 in (368.05 mm)","Range":"PowerPact","Width":"16.54 in (420.12 mm)","Height":"16.24 in (412.50 mm)","AWG gauge":"4 x AWG 3/0...600 kcmil aluminium/copper 4 x AWG 3/0...500 kcmil copper","Standards":"UL CSA NEMA NMX J-266 IEC 60947-2","Control Type":"Operating handle","Product name":"PowerPact R","Mounting mode":"I-Line bracket)","Quality labels":"CE","Trip unit name":"MicroLogic 6.0 P","Number of Poles":"3P","Number of slots":"2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 voltage release MN or MX plug-in)","lifecycle_stage":"unknown","Local signalling":"Alarm 1 LED yellow)long-time pick up) 1 LED red)long-time pick up) Trip causes 1 LED red) 1 LED red)digital ammeter) Ground indicator 1 LED red) Phase-loading LED green)load balancing)","Mounting Support":"Bracket","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Breaking capacity":"AIR 65 kA 240 V AC 50/60 Hz UL 489 AIR 65 kA 480 V AC 50/60 Hz UL 489 AIR 65 kA 600 V AC 50/60 Hz UL 489 Icu 85 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 70 kA 380/415 V AC 50/60 Hz IEC 60947-2","Network Frequency":"50/60 Hz","Tightening torque":"442.5 lbf.in (50 N.m) 0.1...0.5 in² (95...300 mm²) (4 x AWG 3/0...600 kcmil)","Device Application":"Distribution","Line Rated Current":"1200 A","Operating altitude":"< 6561.68 ft (2000 m) without derating 13123.36 ft (4000 m) with derating","Terminal identifier":"AL1200R53K","Trip unit technology":"Electronic, power, MicroLogic 6.0 P, LSIG","Utilisation category":"Category A","Electrical connection":"I-Line connection, line Lugs, load","Nbr. of units in pkg.":"1","Breaking capacity code":"K","Communication interface":"Modbus","IP degree of protection":"IP40","Continuous current rating":"100 %","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes IEC 60947-2","Circuit breaker application":"HACR rated","Power wire stripping length":"1.2 in (30 mm)","[Ui] rated insulation voltage":"750 V IEC 60947-2","[Ue] rated operational voltage":"600 V AC 50/60 Hz UL 489","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"65 kA 240 V AC 50/60 Hz IEC 60947-2 55 kA 380/415 V AC 50/60 Hz IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe755b96a3fc4b2ec01f1ce713eda84d.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RKA36120CU64AE1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RKA36120CU64AE1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RKA36120CU64AE1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}