{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RM35ATW5MW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RM35ATW5MW","canonicalUrl":"https://aoctrl.com/schneider/RM35ATW5MW","factsUrl":"https://aoctrl.com/api/mcp/products/RM35ATW5MW","rawCanonicalId":null},"summary":{"shortDescription":"HARMONY, MODULAR TEMPERATURE 3-P","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Width":"1.4 in (35 mm)","Category":"US10CP222380","Standards":"NF EN 60255-6 IEC 60255-6","Relay Type":"Temperature control relays","Relay name":"RM35AT","Reset Time":"8 s","Time Delay":"Adjustable 1...10 s Tt- time delay upon fault","Control Type":"Without test button","Response time":"500 ms (in case of 3-phase fault) 500 ms (on disappearance of fault)","Operating rate":"<= 360 operations/hour full load","Output contacts":"2 NO","lifecycle_stage":"current","Housing material":"Polycarbonate","Installed device":"Pt 100 probe cable length 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1","Local Signalling":"1 LED Green power ON 1 LED Yellow correct temperature (high R1)/(low R2) 1 LED Yellow phases of relay","Mounting support":"35 mm symmetrical DIN rail conforming to IEC 60715","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Control Relays","Shock resistance":"15 gn 11 ms IEC 60255-21-1","Supply frequency":"50/60 Hz +/- 10 %","Time delay range":"0.1...10 s adjustable 0...10 % of the full scale value)","Contacts material":"Cadmium free","Delay At Power Up":"0.2 s","Measurement range":"208...480 V AC +/- 1...46 °C","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1","Operating position":"Any position without derating","Measurement accuracy":"+/- 2 °C","Utilisation category":"AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1","Vibration resistance":"0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f= 57.6...150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1","Electrical durability":"100000 cycles","Mechanical durability":"30000000 cycles","Nbr. of units in pkg.":"1","Supply voltage limits":"20.4...264 V AC 21.6...264 V DC","Nominal Output Current":"5 A","Temperature probe type":"Pt 100 - 3-wire","Connections - terminals":"Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end","Dielectric test voltage":"2 kV AC 50 Hz, 1 min","IP degree of protection":"IP20 IEC 60529 terminals) IP30 IEC 60529 casing)","Immunity to microbreaks":"10 ms","Switching capacity in VA":"1250 VA","Maximum switching voltage":"250 V AC/DC","Minimum switching current":"10 mA 5 V DC","Product or Component Type":"Elevator machine room temperature control relay","[Us] rated supply voltage":"24...240 V AC/DC","Non-dissipating shock wave":"4 kV","Relay monitored parameters":"Phase sequence Phase failure detection Under temperature: -1...11°C Over temperature: 34...46°C","[Un] rated nominal voltage":"24...240 V AC/DC 50/60 Hz, non self-powered","Operating Voltage Tolerance":"- 10 % + 10 % Un DC - 15 % + 10 % Un AC","Resistance across terminals":"600 kOhm 3-phase 1.33 kOhm temperature","Product Specific Application":"For elevator machine rooms and 3-phase supplies","Electromagnetic compatibility":"Emission standard for industrial environments IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2","[Ui] rated insulation voltage":"400 V IEC 60664-1","Maximum power consumption in W":"0.6 W DC","Maximum power consumption in VA":"3.5 VA AC","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Operation":"-4...122 °F (-20...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$91.47","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9231697e81936bfdfa5ee91d4758ca92.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RM35ATW5MW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RM35ATW5MW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RM35ATW5MW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}