{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RM35JA32MR","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RM35JA32MR","canonicalUrl":"https://aoctrl.com/schneider/RM35JA32MR","factsUrl":"https://aoctrl.com/api/mcp/products/RM35JA32MR","rawCanonicalId":null},"summary":{"shortDescription":"SQD RM35JA32MR AMP MON RELAY|SQD RM35JA32MR AMP MON RELAY 24-240VAC IN 8ADPDT 0.15-1","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Width":"1.4 in (35 mm)","Category":"US10CP222380","Standards":"IEC 60255-1","Insulation":"Between supply and measurement","Relay Type":"Current control relay","Relay name":"RM35JA","Reset time":"1500 ms at maximum voltage","Control Type":"With test button","Output contacts":"2 C/O","Time delay type":"Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault","lifecycle_stage":"current","Housing material":"Polycarbonate","Local signalling":"LED (yellow) for relay ON LED (green) for power ON","Mounting support":"35 mm DIN rail conforming to IEC 60715","Pollution degree":"3 IEC 60664-1 3 UL 508","Range of Product":"Harmony Control Relays","Shock resistance":"15 gn 11 ms) not in operation IEC 60068-2-27 5 gn 11 ms) in operation IEC 60068-2-27","Contacts material":"Cadmium free","Measurement range":"150 mA...15 A AC/DC","Relative humidity":"93...97 % 77...131 °F (25...55 °C) IEC 60068-2-30","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1","Utilisation category":"AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1","Vibration resistance":"0.075 mm 10...58.1 Hz) not in operation IEC 60068-2-6 1 gn 10...58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1...150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1...150 Hz) in operation IEC 60068-2-6","Electrical durability":"100000 cycles","Mechanical durability":"10000000 cycles","Nbr. of units in pkg.":"1","Supply voltage limits":"20.4...264 V AC/DC","Nominal Output Current":"8 A","Connections - terminals":"Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end","Dielectric test voltage":"2.5 kV AC 50 Hz, 1 min IEC 60255-27","IP degree of protection":"IP20 IEC 60529 terminals) IP50 IEC 60529 front panel) IP30 IEC 60529 housing)","Immunity to microbreaks":"50 ms","Maximum measuring cycle":"100 ms measurement cycle as true rms value","Safety reliability data":"MTTFd = 296.8 years B10d = 270000","Switching capacity in VA":"2000 VA","Internal input resistance":"0.015 Ohm 0.005 Ohm 0.05 Ohm","Maximum switching current":"8 A AC","Maximum switching voltage":"250 V AC","Minimum switching current":"10 mA 5 V DC","Product or Component Type":"Current control relay","Switching threshold drift":"100 MOhm 500 V DC IEC 60255-27","[Us] rated supply voltage":"24...240 V AC/DC 50/60 Hz, non self-powered","Relay monitored parameters":"Overcurrent or undercurrent in window mode Overcurrent or undercurrent detection","Operating Voltage Tolerance":"- 15 % + 10 % Un","Resistance across terminals":"0.005 Ohm E3-M terminals 0.015 Ohm E2-M terminals 0.05 Ohm E1-M terminals","Environmental characteristic":"3K3 C","Contacts type and composition":"2 C/O","Electromagnetic compatibility":"Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to IEC 61000-6-3","Maximum power consumption in W":"1.5 W DC","Maximum power consumption in VA":"3.5 VA","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...122 °F (-20...50 °C) 60 Hz -4...140 °F (-20...60 °C) 50 Hz","Setting accuracy of the switching threshold":"+/- 10 % of the full scale"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$66.04 – $178.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3048874d7d6e11933043dac1cc43b01.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RM35JA32MR/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RM35JA32MR","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RM35JA32MR when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}