{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RM35S0MW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RM35S0MW","canonicalUrl":"https://aoctrl.com/schneider/RM35S0MW","factsUrl":"https://aoctrl.com/api/mcp/products/RM35S0MW","rawCanonicalId":null},"summary":{"shortDescription":"HARMONY, MODULAR SPEED CONTROL R","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Width":"1.4 in (35 mm)","Marking":"CE : EMC 89/336/EEC CE : 73/23/EEC","Category":"US10CP222380","Polarity":"Reversible polarity on DC supply","Standards":"NF EN 60255-6 IEC 60255-6","Hysteresis":"5 % threshold","Relay Type":"Speed control relays","Relay name":"RM35S","Status LED":"1 LED Green power ON 1 LED Yellow inhibit 1 LED Yellow relay (R)","Time Delay":"Adjustable 0.6...60 s Ti- inhibition time delay upon startup","Control Type":"Without test button","Response time":"15 ms max (on crossing the threshold)","Operating rate":"<= 360 operations/hour full load","Input frequency":"0.0017...20 Hz","Output contacts":"1 C/O","Repeat accuracy":"+/- 0.5 % input and measurement circuit +/- 0.5 % time delay","lifecycle_stage":"current","Housing material":"Polycarbonate","Impulse duration":">= 5 ms high state >= 5 ms low state","Mounting support":"35 mm symmetrical DIN rail conforming to IEC 60715","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Control Relays","Shock resistance":"15 gn 11 ms IEC 60255-21-1","Supply frequency":"50/60 Hz +/- 10 %","Time delay range":"0.6...60 s adjustable on energisation 0...10 % of the full scale value)","Contacts material":"Cadmium free","Delay At Power Up":"0.05 s","Measurement error":"+/- 0.1 %/°C with temperature variation < +/- 1 % over the whole range with voltage variation","Measurement range":"0.05...600 s","Relative humidity":"95 % 131 °F (55 °C) IEC 60068-2-30","Threshold setting":"10...100 %","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1","Operating position":"Any position without derating","Input compatibility":"3-wire sensor (E1) PNP or NPN, 12 V, 50 mA NAMUR sensor (E2), 12 V, 1.5 kOhm Voltage input (E1), 0...30 V, 9.5 kOhm >= 4.5 V Volt-free contact input (E1), 12 V, 9.5 kOhm","Measurement accuracy":"+/- 10 % of the full scale value","Overvoltage category":"III conforming to IEC 60664-1","Utilisation category":"AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1","Vibration resistance":"0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f= 57.6...150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1","Electrical durability":"100000 cycles","Insulation resistance":"> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1","Mechanical durability":"30000000 cycles","Nbr. of units in pkg.":"1","Supply voltage limits":"20.4...264 V AC/DC","Nominal Output Current":"5 A","Connections - terminals":"Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end","Dielectric test voltage":"2 kV AC 50 Hz","IP degree of protection":"IP20 IEC 60529 terminals) IP30 IEC 60529 casing)","Immunity to microbreaks":"50 ms","Rest Time In Memory Mode":"50 ms contact S2 in memory mode on time delay 1 s supply Un in memory mode on time delay","Switching capacity in VA":"1250 VA","Maximum switching voltage":"250 V AC/DC","Minimum switching current":"10 mA 5 V DC","Product or Component Type":"Speed control relay","Supply Voltage For Sensor":"11.5...12.5 V","Non-dissipating shock wave":"4 kV","Relay monitored parameters":"Overspeed Underspeed","[Un] rated nominal voltage":"24...240 V AC/DC 50/60 Hz, non self-powered","Operating Voltage Tolerance":"- 15 % + 10 % Un","Electromagnetic compatibility":"Emission standard for industrial environments IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2","[Ui] rated insulation voltage":"250 V IEC 60664-1","Maximum power consumption in W":"3 W DC","Maximum power consumption in VA":"5 VA AC","Maximum supply current for sensors":"40 mA < 24 V AC 77 °F (25 °C) 40 mA < 24 V DC 77 °F (25 °C) 50 mA 24...240 V AC 50 mA 24...240 V DC","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Operation":"-4...122 °F (-20...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$72.39","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/39ffda4cf2b73ead2141f3ab9d1bb784.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RM35S0MW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RM35S0MW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RM35S0MW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}