{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RM35UA11MW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RM35UA11MW","canonicalUrl":"https://aoctrl.com/schneider/RM35UA11MW","factsUrl":"https://aoctrl.com/api/mcp/products/RM35UA11MW","rawCanonicalId":null},"summary":{"shortDescription":"Modular 1 phaseVoltage control relay, Harmony, 5A, 2CO, range 0.05...5V, 24..240V AC DC|Modular 1 phaseVoltage control relay, Harmony, 5A, 2CO, range 0.05...5V, 24..240V AC DC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Width":"1.4 in (35 mm)","Category":"US10CP222380","Polarity":"Non reversible polarity on DC supply","Standards":"IEC 60255-6","Directives":"73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility","Hysteresis":"5...50 % threshold setting","Relay Type":"Multifunction voltage control relay","Relay name":"RM35UA","Reset time":"1500 ms time delay","Time Delay":"Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault","Control Type":"Without test button","Operating rate":"<= 360 operations/hour full load","Quality labels":"CE","Output contacts":"2 C/O","Repeat accuracy":"+/- 0.5 % input and measurement circuit +/- 2 % time delay","lifecycle_stage":"current","Housing material":"Polycarbonate","Local signalling":"LED (green) for power ON LED (yellow) for relay ON","Mounting support":"35 mm symmetrical DIN rail conforming to IEC 60715","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Control Relays","Shock resistance":"5 gn IEC 60068-2-27","Delay At Power Up":"600 ms","Measurement error":"+/- 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation","Measurement range":"0.05...5 V AC/DC","Relative humidity":"95 % 131 °F (55 °C) IEC 60068-2-30","Sensitivity scale":"0.05...0.5 V E1-M terminals 0.3...3 V E2-M terminals 0.5...5 V E3-M terminals","Threshold setting":"10...100 %","Tightening torque":"5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1","Operating position":"Any position without derating","Measurement accuracy":"+/- 10 % of the full scale value","Overvoltage category":"III conforming to IEC 60664-1","Utilisation category":"AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1","Vibration resistance":"0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6...150 Hz) conforming to IEC 60255-21-1","Electrical durability":"100000 cycles","Insulation resistance":"> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 > 1 MOhm 500 V DC between supply and measurement IEC 60664-1","Mechanical durability":"30000000 cycles","Nbr. of units in pkg.":"1","Supply voltage limits":"20.4...264 V AC/DC","Nominal Output Current":"5 A","Connections - terminals":"Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end","Dielectric test voltage":"2 kV AC 50 Hz, 1 min IEC 60255-5 2 kV AC 50 Hz, 1 min IEC 60664-1","IP degree of protection":"IP20 IEC 60529 terminals) IP30 IEC 60529 casing)","Immunity to microbreaks":"10 ms","Maximum measuring cycle":"30 ms measurement cycle as true rms value","Power consumption in VA":"0...3.5 VA AC","Safety reliability data":"B10d = 290000 MTTFd = 308.2 years","Switching capacity in VA":"1250 VA","Control circuit frequency":"40...70 Hz +/- 10 %","Maximum switching current":"5 A AC/DC","Maximum switching voltage":"250 V AC/DC","Minimum switching current":"10 mA 5 V DC","Product or Component Type":"Voltage control relay","Non-dissipating shock wave":"4 kV IEC 60255-5 4 kV IEC 60664-1 4 kV IEC 61000-4-5","Relay monitored parameters":"Overvoltage or undervoltage detection","[Un] rated nominal voltage":"24...240 V AC/DC 50/60 Hz, non self-powered","Operating Voltage Tolerance":"- 15 % + 10 % Un","Resistance across terminals":"30 mOhm E2-M terminals 5 mOhm E1-M terminals 50 mOhm E3-M terminals","Contacts type and composition":"2 C/O","Electromagnetic compatibility":"Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2","[Ui] rated insulation voltage":"250 V IEC 60664-1 600 V IEC 60664-1","Maximum power consumption in W":"0.6 W DC","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...122 °F (-20...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$52.07","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3048874d7d6e11933043dac1cc43b01.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RM35UA11MW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RM35UA11MW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RM35UA11MW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}