{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"RM4TU02","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"RM4TU02","canonicalUrl":"https://aoctrl.com/schneider/RM4TU02","factsUrl":"https://aoctrl.com/api/mcp/products/RM4TU02","rawCanonicalId":null},"summary":{"shortDescription":"Relay, Network Control, RM4-T3PH, 3P, 380 - 440VAC|Relay, Network Control, RM4-T3PH, 3-Pole, 380 - 440 Volt AC, without Time Delay","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"3.1 in (80 mm)","Width":"0.9 in (22.5 mm)","Height":"3.07 in (78 mm)","Marking":"CE","Category":"22376-RELAYS-MEASUREMENT(RM4)","Standards":"EN/IEC 60255-6","Directives":"73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility","Hysteresis":"5 % fixed de-energisation threshold","Relay Type":"Control relay","Relay name":"RM4-T","9 Mm Pitches":"2.5","Output contacts":"2 C/O","Time delay type":"Without","lifecycle_stage":"current","Number of cables":"2","Pollution degree":"3 IEC 60664-1","Range of Product":"Harmony Relay","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50/60 Hz +/- 5 %","Time delay drift":"<= 0.5 % within the measuring range","Contacts material":"90/10 silver nickel contacts","Delay At Power Up":"650 ms","Poles description":"3P","Relative humidity":"15...85 % 3K3 IEC 60721-3-3","Switching voltage":"250 V AC","Tightening torque":"5.3...9.7 lbf.in (0.6...1.1 N.m)","Operating position":"Any position without derating","Output relay state":"Tripped, fault present","Overvoltage category":"III conforming to IEC 60664-1","Vibration resistance":"0.35 ms (f= 10...55 Hz) conforming to IEC 60068-2-6","Mechanical durability":"30000000 cycles","Nbr. of units in pkg.":"1","Connections - terminals":"Screw terminals, 2 x 1.5 mm²flexible with cable end Screw terminals, 2 x 2.5 mm²flexible without cable end","Dielectric test voltage":"2.5 kV","IP degree of protection":"IP20 IEC 60529 terminals) IP50 IEC 60529 casing)","Maximum measuring cycle":"80 ms","Switching capacity in mA":"10 mA 12 V","Maximum switching voltage":"440 V AC","Product or Component Type":"Industrial measurement and control relays","Switching threshold drift":"<= 0.5 % within the measuring range","Non-dissipating shock wave":"4.8 kV","Relay monitored parameters":"Phase sequence Undervoltage detection Phase failure detection","Product Specific Application":"For 3-phase supply","Contacts type and composition":"2 C/O","Electromagnetic compatibility":"Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Resistance to electrostatic discharge - test level: 6 kV (contact) conforming to IEC 61000-4-2 level 3 Resistance to electrostatic discharge - test level: 8 kV (air) conforming to IEC 61000-4-2 level 3","Resistance to fast transients":"2 kV IEC 61000-4-4 level 3","[Ui] rated insulation voltage":"500 V IEC","Control threshold undervoltage":"300...430 V","Disturbance radiated/conducted":"CISPR 22 - class A CISPR 11 group 1 - class A","Setting accuracy of time delay":"10 P","Terminals description ISO n°1":"ALT (25-26-28)OC (L1-L2-L3)CO (15-16-18)OC","Terminals description ISO n°2":"(L1-L2-L3)CO (11-12-14)OC (21-22-24)OC ALT","[Ie] rated operational current":"2 A 158 °F (70 °C) 24 V DC-13 IEC 60947-5-1/1991 2 A 158 °F (70 °C) 24 V DC-13 VDE 0660 3 A 158 °F (70 °C) 115 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 115 V AC-15 VDE 0660 3 A 158 °F (70 °C) 24 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 24 V AC-15 VDE 0660 3 A 158 °F (70 °C) 250 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 250 V AC-15 VDE 0660 0.1 A 158 °F (70 °C) 250 V DC-13 IEC 60947-5-1/1991 0.1 A 158 °F (70 °C) 250 V DC-13 VDE 0660 0.3 A 158 °F (70 °C) 115 V DC-13 IEC 60947-5-1/1991 0.3 A 158 °F (70 °C) 115 V DC-13 VDE 0660","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) IEC 61000-4-3 level 3","Ambient air temperature for operation":"-4...149 °F (-20...65 °C)","Resistance to electrostatic discharge":"6 kV contact IEC 61000-4-2 level 3 8 kV air IEC 61000-4-2 level 3","Setting accuracy of the switching threshold":"+/-3 %","[Ith] conventional free air thermal current":"8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/101e2e365342a4eb40152b8f1b9bd779.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/RM4TU02/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/RM4TU02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/RM4TU02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}