{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"S201DC-K6","brand":"ABB","brandSlug":"abb","productSlug":"S201DC-K6","canonicalUrl":"https://aoctrl.com/abb/S201DC-K6","factsUrl":"https://aoctrl.com/api/mcp/products/S201DC-K6","rawCanonicalId":null},"summary":{"shortDescription":"ABB S201DC-K6, 1-pole miniature circuit breaker, trip curve K, 6 A, 60 V DC, 10 kA interrupting rating, DIN rail mount.","salesMarkdown":"## DIN-rail panel integration Single-pole width (roughly 17.5 mm per module) fits a compact panel layout. The 60 V DC rating covers the common 48 V and 24 V DC control buses found in industrial automation panels, plus nominal 60 V battery-backed supplies. The S201DC-K6 is listed as current production. No official successor has been published — this remains the active order code for the 6 A K-curve DC MCB in the S200 series.","metaTitle":"ABB S201DC-K6 MCB 1P K 6A 60V DC, 10 kA","metaDescription":"ABB S201DC-K6 miniature circuit breaker, 1-pole, trip curve K, 6 A, 60 V DC, 10 kA interrupting rating. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Amps":"6","Type":"Trip Curve K","Poles":"1","Mounting":"DIN Rail","Volts DC":"60","lifecycle_stage":"current","Interrupt Rating AC":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/S201DC-K6/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of S201DC-K6?","answer":"The interrupting rating is 10 kA on AC circuits."},{"question":"What does trip curve K mean for this breaker?","answer":"Trip curve K means the magnetic trip threshold is 8 to 12 times the rated current (6 A), so it tolerates the inrush of inductive loads like small motors and transformers without nuisance tripping."},{"question":"Where can I buy S201DC-K6?","answer":"This part is available to order against an RFQ through independent distribution channels. Current pricing and availability are confirmed at quote time."},{"question":"Will S201DC-K6 drop into a panel specified around S201MUC-K2 without rewiring?","answer":"Both are single-pole K-curve MCBs on DIN rail, but the S201MUC-K2 is rated 2 A at 277 V AC / 250 V DC with a 6 kA AC interrupting rating, while the S201DC-K6 is 6 A at 60 V DC with 10 kA AC interrupting. The footprint and mounting are the same, but the voltage and current ratings differ — verify the branch circuit's nominal voltage and load current before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/S201DC-K6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/S201DC-K6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}