{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"S802S-C10","brand":"ABB","brandSlug":"abb","productSlug":"S802S-C10","canonicalUrl":"https://aoctrl.com/abb/S802S-C10","factsUrl":"https://aoctrl.com/api/mcp/products/S802S-C10","rawCanonicalId":null},"summary":{"shortDescription":"ABB S802S-C10 High Performance Miniature Circuit Breaker, 2 Pole, 10 Amp, Trip Curve C, 230 VAC, 50 kA interrupting rating, DIN rail mount.","salesMarkdown":"## Integrator note: 10 A, Curve C, 50 kA The ABB S802S-C10 is a 2-pole high-performance miniature circuit breaker rated at 10 A with Trip Curve C, designed for DIN-rail mounting in distribution panels and control cabinets. Its 50 kA interrupting capacity at 230 VAC means it can safely clear a fault up to that level without upstream devices needing to trip — critical for high-fault-current installations where selectivity and SCCR headroom matter. Curve C trips between 5 and 10 times rated current, making it the standard choice for moderate inrush loads like small motors, transformers, and lighting banks — not for purely resistive circuits where Curve B would suffice, nor for heavy inductive starts that need Curve D. ## Panel integration Snap-on DIN rail mounting (per EN 60715) simplifies panel assembly — no screws or tools needed for installation, and the compact 2-pole footprint leaves room for adjacent breakers or auxiliary devices in a crowded enclosure.","metaTitle":"S802S-C10 ABB High Performance MCB, 2P 10A Curve C, 50 kA","metaDescription":"ABB S802S-C10 miniature circuit breaker, 2-pole, 10 A, Trip Curve C, 50 kA interrupting capacity at 230 VAC. DIN rail mount. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Amps":"10","Type":"Trip Curve C","Poles":"2","title":"S802S-C10","Mounting":"DIN Rail","Volts AC":"230","description":"High Performance Circuit Breaker, 2P, 10A|High Performance Miniature Circuit Breaker, 2 Pole, 10 Amp","lifecycle_stage":"current","Interrupt Rating AC":"50 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0affc6ee7b7922433dd8ad17f09399ee.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the closest functional alternative to S802S-C10 — the S202M-B10?","answer":"The S202M-B10 is a 2-pole 10 A breaker on a Curve B trip characteristic, with a 6 kA interrupting rating at 277 VAC — significantly lower fault-clearing capacity than the S802S-C10's 50 kA. It will not drop into a panel specified for the S802S-C10 without verifying the available fault current and trip coordination; the Curve B trips faster on moderate overloads, which may cause nuisance tripping on motor or transformer inrush where Curve C was originally selected."},{"question":"What is S802S-C10's interrupting rating?","answer":"The S802S-C10 is rated for 50 kA interrupting capacity at 230 VAC, suitable for high-fault-current installations."},{"question":"Will S802S-C10 drop into a panel specified around S202M-B10 without rewiring?","answer":"Both breakers share the same 2-pole DIN-rail footprint and 10 A rating, so physical fit and conductor sizing are identical. However, the S802S-C10's 50 kA interrupting rating far exceeds the S202M-B10's 6 kA, so the panel's available fault current must be verified — if it exceeds 6 kA, the S202M-B10 was underspecified and the S802S-C10 is the correct upgrade. Trip curve difference (C vs B) may also require coordination study."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/S802S-C10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/S802S-C10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}