{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"S8FS-G15048CD","brand":"Omron","brandSlug":"omron","productSlug":"S8FS-G15048CD","canonicalUrl":"https://aoctrl.com/omron/S8FS-G15048CD","factsUrl":"https://aoctrl.com/api/mcp/products/S8FS-G15048CD","rawCanonicalId":null},"summary":{"shortDescription":"Omron S8FS-G Series switching power supply, DIN Rail, Single Phase, 100-240 V AC input, 48 V DC output at 3.3 A, 150 W rated power.","salesMarkdown":"The Omron S8FS-G15048CD is a 150 W DIN-rail switching power supply delivering 48 V DC at 3.3 A from a single-phase 100–240 V AC input. That 150 W figure is the continuous rated output — it's the number that governs whether this supply carries your load without derating. The 3.3 A at 48 V DC is the current you can draw continuously; if your 48 V DC bus pulls more than that, you need the next frame up. Input frequency range is 47–450 Hz, so it handles both 50/60 Hz mains and higher-frequency generator or UPS outputs without complaint. The supply is built for panel integration — DIN-rail mount, aluminum and stainless steel housing, screw terminals accepting 12–20 AWG wire. The housing material matters in washdown or corrosive environments: the stainless steel resists rust, and the aluminum body acts as a heatsink. Green LED status indicator gives a quick visual on output health. Protection suite includes overload, overvoltage, and automatic reset — meaning it recovers on its own after a fault clears, which reduces nuisance service calls on remote or unattended panels. Series operation is supported, so you can stack two units for higher voltage if needed. ## Reliability and lifecycle read Hold-up time is specified at 11 msec minimum at full load, 55 msec at lighter load — enough to ride through most line dips without dropping the DC bus. Start-up time is 1,000 msec maximum, so factor that into your power-up sequence if the downstream loads need a staggered ramp. ## Approvals and compliance documentation This supply carries UL 508 listing and UL 60950-1 recognition, plus cUL, cUR, and VDE marks. It also meets SEMI F47-0706 voltage sag immunity at 200 V AC input — a key spec for semiconductor fab equipment where a 20 msec dip can't drop the tool. The approvals package covers North America (UL/cUL), Europe (VDE), and the semiconductor industry standard, so it's accepted in most industrial control panels and OEM machinery. Efficiency hits 88% at 230 V AC, which keeps the heat rise manageable in a sealed enclosure. Output noise is capped at 120 mV — clean enough for most PLC and sensor loads, but verify against sensitive analog circuits.","metaTitle":"Omron S8FS-G15048CD DIN Rail Power Supply, 150 W, 48 V DC, 3","metaDescription":"Omron S8FS-G15048CD switching power supply, 150 W, 48 V DC output at 3.3 A, single-phase 100-240 V AC input, DIN rail mount, UL 508 listed, 135,000 hr MTBF. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"Brand":"OMRON","Phase":"Single","Series":"S8FS- G","Mounting":"DIN Rail","Standards":"cUL; cUR; SEMI F47-0706 (200 VAC input); UL 508 (Listing); UL: UL 60950-1 (Recognition); VDE","Input Voltage":"100 to 240V AC","Overall Depth":"7.76 in","Overall Width":"1.74 in","Overall Height":"3.82 in","lifecycle_stage":"mature","Current - Inrush":"28 A","Current - Output":"3.3 A","Housing Material":"Aluminum; Stainless Steel","Special Features":"Automatic Reset; LED Diagnostic Indicators; Overload Protection; Overvoltage Protection; Series Operation","Status Indicator":"Green LED","Power Supply Style":"Switching","Wire Size - Maximum":"12 AWG","Wire Size - Minimum":"20 AWG","Output Power - Rated":"150 W","Wire Connection Type":"Screw Terminals","Hold Up Time - Minimum":"11 msec; 55 msec","Output Noise - Maximum":"120 mV","Start Up Time - Maximum":"1,000 msec","Output Voltage - Nominal":"48 V DC","Input Frequency - Minimum":"47 Hz","Input Frequency - Nominal":"50/60 Hz","Input Frequency - Maximuim":"450 Hz","Maximum Efficiency @ 230V AC":"88 %","Operating Temperature - Maximum":"158 °F","Operating Temperature - Minimum":"-4 °F","Mean Time Between Failures (MTBF)":"135,000 hr"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$64.77 – $130.56","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/S8FS-G15048CD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the S8FS-G15048CD and what is the lead time?","answer":"The S8FS-G15048CD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price."},{"question":"What compliance documentation does Omron provide for the S8FS-G15048CD?","answer":"The S8FS-G15048CD carries UL 508 listing, UL 60950-1 recognition, cUL, cUR, VDE approvals, and meets SEMI F47-0706 voltage sag immunity. These certifications cover North American and European regulatory requirements for industrial control equipment."},{"question":"What is the input phase and voltage range for the S8FS-G15048CD?","answer":"The S8FS-G15048CD accepts single-phase input from 100 to 240 V AC, 47–450 Hz. It operates on standard 50/60 Hz mains and can also handle higher-frequency generator or UPS supplies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/S8FS-G15048CD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/S8FS-G15048CD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}