{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"S8VK-G06012","brand":"Omron","brandSlug":"omron","productSlug":"S8VK-G06012","canonicalUrl":"https://aoctrl.com/omron/S8VK-G06012","factsUrl":"https://aoctrl.com/api/mcp/products/S8VK-G06012","rawCanonicalId":null},"summary":{"shortDescription":"Omron S8VK-G series, Standard model, single-phase DIN-rail power supply, 60 W, 12 VDC output at 4.5 A, screw terminals.","salesMarkdown":"The S8VK-G06012: The 12 VDC rail at 4.5 A is sized for control-circuit loads — PLCs, small I/O slices, relays, and indicator banks. The 60 W ceiling limits the total downstream draw; if your BOM sums above 4.5 A at 12 V, step to the next frame in the S8VK-G family. The single-phase input covers standard North American and European line voltages without a transformer tap. Efficiency is rated at 85 %, which keeps heat dissipation manageable inside a sealed panel. Output is adjustable via the front trim pot. Ripple and noise is 150 mV. DIN-rail mount, 32 mm wide — fits a standard TS35 rail. Screw terminals accept 22 to 12 AWG; torque to the manufacturer spec (not listed here, but typical for this class is 0.5–0.6 N·m). The plastic housing carries an IP20 rating, so it is intended for clean, dry indoor enclosures only — no washdown areas. The green LED on the front confirms output is present. Hold-up time is 26 ms minimum (139 ms at nominal load), which keeps the DC bus alive through a half-cycle dropout — enough for the PLC to finish its scan and signal a safe stop. ## Protection and compliance Built-in overload, overvoltage, and automatic reset protection. The unit can be paralleled for redundancy or higher current, and series operation is supported for higher voltage rails. MTBF is rated at 135,000 hours at 25 °C — roughly 15 years of continuous run time. Approvals cover UL 508 and UL 62368-1, CSA C22.2 No. 107.1 and 62368-1, EN 50178, EN 61558-2-16, EN 62368-1, and Lloyd’s Standards EN 60204-1 PELV. CE-marked for the European market. The insulation voltage rating of 3000 VAC between input and output gives confidence for SELV/PELV circuits feeding exposed operator panels. No broker or surplus channel needed. If you are cross-referencing the alternate code S8VKG06012 (same part, different catalog-string convention), it drops in identically — same ratings, same footprint, same approvals.","metaTitle":"Omron S8VK-G06012 Power Supply, 60 W, 12 VDC, 4.5 A, Single-","metaDescription":"Omron S8VK-G06012 single-phase DIN-rail power supply, 60 W, 12 VDC output at 4.5 A. Current production. UL/CSA/CE approved. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"title":"S8VK-G06012","Option":"Standard model","Phases":"Single","series":"S8VK-G","has_mpn":"S8VK-G06012","power_w":"60","Size Max":"12 AWG","Size Min":"22 AWG","depth_mm":"109.982","width_mm":"32.004","height_mm":"89.916","ip_rating":"IP20","power_out":"60 W","standards":"CE; CSA C22.2 No. 107.1/62368-1; cULus; cURus; EN50178; EN61558-2-16; EN62368-1; Lloyd’s Standards EN60204-1 PELV; UL 508/62368-1","mtbf_hours":"135000 h","voltage_in":"100... 240 VAC","Current Out":"4.5 A","Voltage Out":"12 VDC output","description":"OMRON DC Power Supply: DIN Rail, 60 W Output Power - Rated, 4.5 A Current - Output, Single Phase","output_type":"Adjustable","Output Count":"1","Ripple Noise":"0.15 V","frequency_hz":"450","Frequency Min":"47 Hz","mounting_type":"DIN Rail","terminal_type":"Screw Terminals","Voltage In Max":"264 V","Voltage In Min":"85 V","efficiency_pct":"85","input_voltage_v":"240","lifecycle_stage":"current","housing_material":"Plastic","switching_current_a":"32","Temp Operating Max C":"158 °F","Temp Operating Min C":"-40 °F","has_status_indicator":"Green LED","insulation_voltage_v":"3000","output_current_max_a":"4.5","special_features_text":"Automatic Reset; LED Diagnostic Indicators; Overload Protection; Overvoltage Protection; Parallel Capability; Series Operation","Hold Up Time - Minimum Min":"26 msec; 139 msec","Output Noise - Maximum Max":"150 mV","Start Up Time - Maximum Max":"650 msec","mean_time_between_failures_mtbf":"135000 hr"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$43.07 – $118.64","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/S8VK-G06012/alternatives.json"},"ai":{"faq":[{"question":"What approvals does the S8VK-G06012 carry?","answer":"It carries cULus, cURus, CE, CSA C22.2 No. 107.1/62368-1, EN 50178, EN 61558-2-16, EN 62368-1, and Lloyd’s Standards EN 60204-1 PELV. It also complies with UL 508 and UL 62368-1."},{"question":"Can I use the S8VK-G06012 in a panel originally wired for the S8VKG06012?","answer":"Yes. The S8VKG06012 is the same part under an alternate catalog convention — identical ratings, footprint, and wiring. No rewiring or panel modification is needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/S8VK-G06012","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/S8VK-G06012 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:03:49.294Z","lastPublished":"2026-09-02T08:03:49.294Z","indexable":true}}