{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SH31402P02A2100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SH31402P02A2100","canonicalUrl":"https://aoctrl.com/schneider/SH31402P02A2100","factsUrl":"https://aoctrl.com/api/mcp/products/SH31402P02A2100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric SH3 servo motor, SH31402P02A2100, 3900 W continuous power, 3000 rpm at 400 V three-phase, IP65, absolute multiturn SinCos Hiperface encoder, smooth shaft, natural convection cooling.","salesMarkdown":"## Speed-torque envelope across supply voltages The SH31402P02A2100: This SH3 motor delivers 3000 rpm nominal speed at 400 V three-phase with 12.3 N.m nominal torque, and 3600 rpm at 480 V three-phase with 9.7 N.m. At 115 V single-phase it runs 750 rpm with 18.6 N.m; at 230 V single-phase it runs 1500 rpm with 17.1 N.m. The continuous stall torque is 19.5 N.m across the 115...480 V three-phase range, drawing 13.2 A continuous stall current. ## Absolute multiturn encoder — Hiperface interface The encoder is an absolute multiturn SinCos Hiperface type — no homing cycle needed at power-up, position is retained through power cycles. The SinCos analog track gives fine interpolated position feedback for motion control loops; the Hiperface serial protocol carries the multiturn count and diagnostic data. ## IP65 enclosure and natural convection cooling Rated IP65 per IEC 60034-5 on both the motor body and the shaft bushing — the motor withstands washdown and airborne particulates without an external shroud. Cooling is by natural convection only, so no fan noise or filter maintenance, but the thermal budget depends on free airflow around the 140 mm flange housing. ## Mounting and shaft details Mounts on an international standard flange with 140 mm centring collar diameter. The shaft is smooth (no keyway), 24 mm diameter by 50 mm length, with a maximum radial force of 2240 N at 1000 rpm and a maximum axial force of 300 N. The electrical connection uses a rotatable right-angled connector — orientation can be adjusted after mounting.","metaTitle":"Schneider Electric SH31402P02A2100 Servo Motor, 3900 W, IP65","metaDescription":"Schneider Electric SH31402P02A2100 SH3 servo motor, 3900 W continuous power, IP65, absolute multiturn encoder. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors with Brake"],"specifications":{"Phase":"Three phase","title":"SH31402P02A2100","Length":"10.7 in (272.5 mm)","Inertia":"0.0 kg.cm² of brake 12.68 kg.cm² of motor","Category":"US1PC5218359","Shaft end":"Smooth shaft","description":"SH3 servomotor, 140mm, 2 stacks, smooth Shaft, SinCos Multiturn 128, no Brake, angular, IP65/65","Encoder type":"Absolute multiturn SinCos Hiperface","Shaft length":"2.0 in (50 mm)","Holding brake":"Without","Nominal speed":"750 rpm 115 V single phase 1500 rpm 230 V single phase 3000 rpm 400 V three phase 3600 rpm 480 V three phase","Rotor inertia":"12.68 kg.cm²","Nominal torque":"164.6 lbf.in (18.6 N.m) 115 V single phase 151.3 lbf.in (17.1 N.m) 230 V single phase 108.9 lbf.in (12.3 N.m) 400 V three phase 85.9 lbf.in (9.7 N.m) 480 V three phase","Shaft diameter":"0.9 in (24 mm)","Torque constant":"1.47 N.m/A 248 °F (120 °C)","Type of cooling":"Natural convection","lifecycle_stage":"current","Continuous power":"3900 W","Mounting Support":"International standard flange","Sizing reference":"SH31402P","Back emf constant":"101 V/krpm 68 °F (20 °C)","Device short name":"SH3","Motor flange size":"5.5 in (140 mm)","Peak stall torque":"531.9 lbf.in (60.1 N.m) 115...480 V three phase","Stator inductance":"3.855 mH","Stator resistance":"0.6 Ohm","Maximum current Irms":"44.1 A","Nominal output power":"1460 W 115 V single phase 2690 W 230 V single phase 3860 W 400 V three phase 3660 W 480 V three phase","Centring collar depth":"0.1 in (3.5 mm)","Electrical Connection":"Rotatable right angled connector","Electrical connection":"rotatable right angled connector","Nbr. of units in pkg.":"1","Number of motor poles":"5.0","Maximum axial force Fa":"300 N","Output current 3s peak":"44.1 A","Temperature copper hot":"266 °F (130 °C)","Continuous stall torque":"172.6 lbf.in (19.5 N.m) 115...480 V three phase","IP degree of protection":"IP65 motor: conforming to IEC 60034-5 IP65 shaft bushing: conforming to IEC 60034-5","Maximum radial force Fr":"2240 N 1000 rpm 1780 N 2000 rpm 1550 N 3000 rpm","Mounting holes diameter":"0.4 in (11 mm)","Centring collar diameter":"5.1 in (130 mm)","Continuous stall current":"13.2 A","Maximum mechanical speed":"4000 rpm","Network number of phases":"3","Number of mounting holes":"4","Product or Component Type":"Servo motor","Speed feedback resolution":"128 periods","[Us] rated supply voltage":"115...480 V","Circle diameter of the mounting holes":"6.5 in (165 mm)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7841c75ba1138e355aedcc0b21e9d97b.pdf","sourceUrl":"https://www.se.com/be/en/product/SH31402P02A2100/sh3-servomotor-140mm-2-stacks-smooth-shaft-sincos-multiturn-128-no-brake-angular-ip65-65/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for SH31402P02A2100?","answer":"Submit an RFQ against your BOM quantity. No stock-holding claim is made here."},{"question":"What is SH31402P02A2100's listed phase and length?","answer":"The motor is rated for three-phase operation. The overall body length is 10.7 inches (272.5 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SH31402P02A2100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SH31402P02A2100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}