{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SH32051P02F2000","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SH32051P02F2000","canonicalUrl":"https://aoctrl.com/schneider/SH32051P02F2000","factsUrl":"https://aoctrl.com/api/mcp/products/SH32051P02F2000","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric SH3 servo motor, SH32051P02F2000, three-phase, 80 N.m holding torque, 5.5 kW continuous, 38 mm smooth shaft, IP65, Hiperface multiturn absolute encoder.","salesMarkdown":"## What the SH32051P02F2000 actually is It is built as a 5-pole, natural-convection servo in a 14.6 in (370.5 mm) long package, terminating in a straight or rotatable right-angled connector so the same motor drops into cabinets with different cable-routing constraints (cites:,). ## Torque and power envelope — what the BOM line is sized against Holding torque is 708.06 lbf.in (80 N.m), continuous stall torque is 326.6 lbf.in (36.9 N.m) across the 115 to 480 V range, and peak stall torque reaches 973.6 lbf.in (110 N.m) — so a sizing exercise lives inside the 36.9 N.m continuous number with 110 N.m available for short accelerations (cites:,). Continuous power is 5.5 kW, but the nominal output power shifts with the bus: 2510 W at 115 V single phase, 4240 W at 230 V single phase, 5500 W at 400 V three phase, and 5200 W at 480 V three phase, which is the figure that decides which drive rating the SH32051P02F2000 pairs with (cites:,). Nominal torque tracks the same voltage curve — 31.9 N.m at 115 V single phase down to 13.8 N.m at 480 V three phase — and nominal speed climbs from 750 rpm at 115 V single phase to 3600 rpm at 480 V three phase, so the mechanical operating point on the machine is set jointly by the drive bus and the gearbox ratio (cites:,). Peak current is 87.2 A Irms (and the 3-second peak output current is the same figure), which is the number the drive sizing block must clear on the overload profile (cites:,). ## Mechanical fit and forces on the shaft Mounting is via the international standard flange with four 14 mm clearance holes on a 180 mm centring collar, and the shaft is 38 mm diameter by 80 mm long — a smooth shaft, so the coupling choice is a clamp-style or keyed compression hub rather than a keyed bore (cites:,). Maximum radial force is 3730 N at 1000 rpm, falling to 2580 N at 3000 rpm, and maximum axial force is 740 N — these are the loads the gearbox or pulley must respect before the bearing life curve derates the motor (cites:,). ## Sealing, thermal, and what the cabinet has to give it Cooling is natural convection with a 130 °C copper-hot temperature limit, which means the cabinet heat-load calculation must budget for the full 5.5 kW dissipation under stall — no fan is built in, so the enclosure's own airflow carries the thermal load (cites:,).","metaTitle":"Schneider SH32051P02F2000 SH3 servo motor, 80 N.m, 5.5 kW","metaDescription":"Schneider SH32051P02F2000 SH3 servo motor, 80 N.m holding torque, 5.5 kW continuous, IP65, Hiperface multiturn encoder. Quoted to order against the BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors with Brake"],"specifications":{"Phase":"Three phase","title":"SH32051P02F2000","Length":"14.6 in (370.5 mm)","Inertia":"16.0 kg.cm² of brake 71.4 kg.cm² of motor","Category":"US1PC5218359","Shaft end":"Smooth shaft","description":"SH3 servomotor, 205mm, 1 stack, smooth Shaft, SinCos Multiturn 128, Brake, angular, IP54/65","Encoder type":"Absolute multiturn SinCos Hiperface","Shaft length":"3.1 in (80 mm)","Holding brake":"With","Nominal speed":"750 rpm 115 V single phase 1500 rpm 230 V single phase 3000 rpm 400 V three phase 3600 rpm 480 V three phase","Rotor inertia":"87.4 kg.cm²","Holding torque":"708.06 lbf.in (80 N.m)","Nominal torque":"282.3 lbf.in (31.9 N.m) 115 V single phase 239.0 lbf.in (27 N.m) 230 V single phase 154.9 lbf.in (17.5 N.m) 400 V three phase 122.1 lbf.in (13.8 N.m) 480 V three phase","Shaft diameter":"1.5 in (38 mm)","Torque constant":"1.75 N.m/A 248 °F (120 °C)","Type of cooling":"Natural convection","lifecycle_stage":"current","Continuous power":"5500 W","Mounting Support":"International standard flange","Sizing reference":"SH32051P","Back emf constant":"104 V/krpm 68 °F (20 °C)","Device short name":"SH3","Motor flange size":"8.07 in (205 mm)","Peak stall torque":"973.6 lbf.in (110 N.m) 115...480 V three phase","Stator inductance":"2.97 mH","Stator resistance":"0.3 Ohm","Maximum current Irms":"87.2 A","Nominal output power":"2510 W 115 V single phase 4240 W 230 V single phase 5500 W 400 V three phase 5200 W 480 V three phase","Centring collar depth":"0.2 in (4 mm)","Electrical Connection":"Straight connector","Electrical connection":"rotatable right angled connector","Nbr. of units in pkg.":"1","Number of motor poles":"5.0","Maximum axial force Fa":"740 N","Output current 3s peak":"87.2 A","Temperature copper hot":"266 °F (130 °C)","Continuous stall torque":"326.6 lbf.in (36.9 N.m) 115...480 V three phase","IP degree of protection":"IP54 shaft bushing without shaft seal ring: conforming to IEC 60034-5 IP65 motor: conforming to IEC 60034-5 IP65 shaft bushing: conforming to IEC 60034-5","Maximum radial force Fr":"3730 N 1000 rpm 2960 N 2000 rpm 2580 N 3000 rpm","Mounting holes diameter":"0.6 in (14 mm)","Centring collar diameter":"7.09 in (180 mm)","Continuous stall current":"21 A","Maximum mechanical speed":"3800 rpm","Network number of phases":"3","Number of mounting holes":"4","Product or Component Type":"Servo motor","Speed feedback resolution":"128 periods","[Us] rated supply voltage":"115...480 V","Circle diameter of the mounting holes":"8.5 in (215 mm)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/SH32051P02F2000/sh3-servomotor-205mm-1-stack-smooth-shaft-sincos-multiturn-128-brake-angular-ip54-65/"},"ai":{"faq":[{"question":"What does the SH32051P02F2000's torque and power envelope look like at the drive terminals?","answer":"Continuous stall torque is 36.9 N.m and holding torque is 80 N.m across the 115 to 480 V range, with peak stall torque reaching 110 N.m and continuous power at 5.5 kW on the 400 V three-phase bus — the nominal output power and nominal torque both shift with the bus voltage, so the drive sizing block is matched to the 400 V three-phase 5.5 kW / 17.5 N.m point unless a different supply is specified (cites:,)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SH32051P02F2000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SH32051P02F2000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}