{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SR2B202BD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SR2B202BD","canonicalUrl":"https://aoctrl.com/schneider/SR2B202BD","factsUrl":"https://aoctrl.com/api/mcp/products/SR2B202BD","rawCanonicalId":null},"summary":{"shortDescription":"COMPACT SMART RELAY, ZELIO LOGIC","salesMarkdown":null,"metaTitle":"SR2B202BD - Schneider Electric","metaDescription":"COMPACT SMART RELAY, ZELIO LOGIC","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Clock":"With","Checks":"Program memory on each power up","Category":"US1000I22378","LSB value":"39 mV analogue input circuit","Standards":"IEC 61000-4-4 level 3 IEC 60068-2-27 Ea IEC 61000-4-5 IEC 61000-4-6 level 3 IEC 61000-4-11 IEC 61000-4-2 level 3 IEC 61000-4-3 IEC 61000-4-12 IEC 60068-2-6 Fc","Cycle time":"6...90 ms","Backup time":"10 years 77 °F (25 °C)","Clock drift":"12 min/year 32...131 °F (0...55 °C) 6 s/month 77 °F (25 °C)","Load current":"0.5...0.625 A transistor output","Local display":"With","Response time":"<= 1 ms from state 1 to state 0)transistor output","Output voltage":"24 V transistor output","Conversion time":"Smart relay cycle time analogue input circuit","Input impedance":"12 kOhm IB...IG used as analogue input circuit 12 kOhm IB...IG used as discrete input circuit 7.4 kOhm I1...IA and IH...IR discrete input circuit","Repeat accuracy":"+/- 2 % 131 °F (55 °C) analogue input circuit","lifecycle_stage":"current","Conversion error":"+/- 5 % 77 °F (25 °C) analogue input circuit +/- 6.2 % 131 °F (55 °C) analogue input circuit","Pollution degree":"2 IEC 61131-2","Range of Product":"Zelio Logic","Number of Outputs":"8 transistor","Relative Humidity":"95 % without condensation or dripping water","Tightening Torque":"4.4 lbf.in (0.5 N.m)","Counting frequency":"1 kHz discrete input","Operating altitude":"6561.68 ft (2000 m)","Operating distance":"10 m between stations, with screened cable (sensor not isolated) analogue input circuit","Analogue Input Type":"Common mode","Discrete input type":"Resistive","Input compatibility":"3-wire proximity sensors PNP discrete input","Overload protection":"With transistor output","Analogue input range":"0...10 V 0...24 V","Overvoltage category":"III conforming to IEC 60664-1","Analogue input number":"6","Discrete input number":"12 IEC 61131-2 Type 1","Nbr. of units in pkg.":"1","Output voltage limits":"19.2...30 V DC transistor output)","Supply voltage limits":"19.2...30 V","Discrete input current":"4 mA","Discrete input voltage":"24 V DC","Maximum supply current":"100 mA without extension)","Overvoltage protection":"With transistor output","Power dissipation in W":"3 W without extension","Temperature probe type":"NTC 10k 77 °F (25 °C) NTC 1000k 77 °F (25 °C) KTY81 210/220/221/222/250 Pt 500","Connections - terminals":"Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end","IP degree of protection":"IP20 IEC 60529 terminal block) IP40 IEC 60529 front panel)","Immunity to microbreaks":"1 ms","[Ures] residual voltage":"2 V at state 1 transistor output","Short-circuit protection":"With transistor output","Analogue input resolution":"8 bits","Product or Component Type":"Compact smart relay","[Us] rated supply voltage":"24 V DC","Current state 0 guaranteed":"<= 0.75 mA I1...IA and IH...IR discrete input circuit)","Maximum altitude transport":"10000 ft (3048 m)","Voltage state 0 guaranteed":"= 1.2 mA IB...IG used as discrete input circuit) >= 2.2 mA I1...IA and IH...IR discrete input circuit)","Voltage state 1 guaranteed":">= 15 V I1...IA and IH...IR discrete input circuit >= 15 V IB...IG used as discrete input circuit","Maximum permissible voltage":"30 V analogue input circuit","Reverse polarity protection":"With","Environmental characteristic":"EMC directive conforming to IEC 61000-6-2 EMC directive conforming to IEC 61000-6-3 EMC directive conforming to IEC 61000-6-4 EMC directive conforming to IEC 61131-2 zone B Low voltage directive conforming to IEC 61131-2","Disturbance radiated/conducted":"Class B EN 55022-11 group 1","Number or control scheme lines":"0...240 ladder 0...500 FBD","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...104 °F (-20...40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) IEC 60068-2-1 and IEC 60068-2-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$107.95","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/68d4bf8a5690719fa3c1ad4dedb560f3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/SR2B202BD/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SR2B202BD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SR2B202BD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}